The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inhalable magnetic nanoparticles for targeted hyperthermia in lung cancer therapy
Open accessAbstract
Lung cancer (specifically, non-small cell lung cancer; NSCLC) is the leading cause of cancer-related deaths in the United States. Poor response rates and survival with current treatments clearly indicate the urgent need for developing an effective means to treat NSCLC. Magnetic hyperthermia is a non-invasive approach for tumor ablation, and is based on heat generation by magnetic materials, such as superparamagnetic iron oxide (SPIO) nanoparticles, when subjected to an alternating magnetic field. However, inadequate delivery of magnetic nanoparticles to tumor cells can result in sub-lethal temperature change and induce resistance while non-targeted delivery of these particles to the healthy tissues can result in toxicity. In our studies, we evaluated the effectiveness of tumor-targeted SPIO nanoparticles for magnetic hyperthermia of lung cancer. EGFR-targeted, inhalable SPIO nanoparticles were synthesized and characterized for targeting lung tumor cells as well as for magnetic hyperthermia-mediated antitumor efficacy in a mouse orthotopic model of NSCLC. Our results show that EGFR targeting enhances tumor retention of SPIO nanoparticles. Further, magnetic hyperthermia treatment using targeted SPIO nanoparticles resulted in significant inhibition of in vivo lung tumor growth. Overall, this work demonstrates the potential for developing an effective anticancer treatment modality for the treatment of NSCLC based on targeted magnetic hyperthermia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eikenes, L., Bruland, Ø. S., Brekken, C., & Davies, C. D. L. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-1472 · Cited by 251
Cited by
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Magnetic hyperthermia efficiency in the cellular environment for different nanoparticle designs
Di Corato, R., Espinosa, A., Lartigue, L., Tharaud, M., Chat, S., Pellegrino, T., Ménager, C., Gazeau, F., & Wilhelm, C. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.036 · Cited by 412
Abdelaziz, H. M., Gaber, M., Abd-Elwakil, M. M., Mabrouk, M. T., Elgohary, M. M., Kamel, N. M., Kabary, D. M., Freag, M. S., Samaha, M. W., Mortada, S. M., et al. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.036 · Cited by 409
Recent advances in magnetic fluid hyperthermia for cancer therapy
Das, P., Colombo, M., & Prosperi, D. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2018.10.051 · Cited by 329
Mangal, S., Gao, W., Li, T., & Zhou, Q. (2017) · Acta Pharmacologica Sinica · doi:10.1038/aps.2017.34 · Cited by 288
Metadata
- Authors
- Sadhukha, T., Wiedmann, T. S., & Panyam, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 34
- Issue
- 21
- Pages
- 5163-5171
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2076297387
- Cited by
- 250
- References
- 1
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inhalable magnetic nanoparticles for targeted hyperthermia in lung cancer therapy. https://app.cochat.ai/papers/10.1016/j.biomaterials.2013.03.061
- The paper
- Sadhukha, T., Wiedmann, T. S., & Panyam, J. (2013). Inhalable magnetic nanoparticles for targeted hyperthermia in lung cancer therapy. Biomaterials. https://doi.org/10.1016/j.biomaterials.2013.03.061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.