An on-chip model of protein paracellular and transcellular permeability in the microcirculation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Recent therapeutic success of large-molecule biologics has led to intense interest in assays to measure with precision their transport across the vascular endothelium and into the target tissue. Most current in vitro endothelial models show unrealistically large permeability coefficients due to a non-physiological paracellular transport. Thus, more advanced systems are required to better recapitulate and discern the important contribution of transcellular transport (transcytosis), particularly of pharmaceutically-relevant proteins. Here, a robust platform technology for the measurement of transport through a human endothelium is presented, which utilizes in vitro microvascular networks (MVNs). The self-assembled MVNs recapitulate the morphology and junctional complexity of in vivo capillaries, and express key endothelial vesicular transport proteins. This results in measured permeabilities to large molecules comparable to those observed in vivo, which are orders of magnitude lower than those measured in transwells. The permeability of albumin and immunoglobulin G (IgG), biopharmaceutically-relevant proteins, is shown to occur primarily via transcytosis, with passage of IgG regulated by the receptor FcRn. The physiological relevance of the MVNs make it a valuable tool to assess the distribution of biopharmaceuticals into tissues, and may be used to prioritize candidate molecules from this increasingly important class of therapeutics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FINE STRUCTURAL LOCALIZATION OF A BLOOD-BRAIN BARRIER TO EXOGENOUS PEROXIDASE
Reese, T. S., & Karnovsky, M. J. (1967) · The Journal of Cell Biology · doi:10.1083/jcb.34.1.207 · Cited by 2,629 · cited 1×
“Similar to capillaries in vivo [34], the MVNs show junctions with clefts of approximately 10 nm, here observed to be bridged and become smaller in the presence of, what are most likely, adherens or tight junctions (Fig.”
BackgroundFcRn: the neonatal Fc receptor comes of age
Roopenian, D. C., & Akilesh, S. (2007) · Nature Reviews Immunology · doi:10.1038/nri2155 · Cited by 2,346 · cited 2×
“This receptor, expressed in both endothelial and epithelial cells, plays a key role in governing the long half-life of these two serum proteins, by salvaging them from lysosomal degradation upon binding within the acidified endosome [11].”
BackgroundMethodMicrovascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183 · cited 1×
“All permeability measurements were performed with interal hydrostatic pressures kept below 50 Pa, in a range where no solute filtration should take place [14].”
MethodMonoclonal Antibody Pharmacokinetics and Pharmacodynamics
Wang, W., Wang, E., & Balthasar, J. (2008) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2008.170 · Cited by 978
Biodistribution Mechanisms of Therapeutic Monoclonal Antibodies in Health and Disease
Tabrizi, M., Bornstein, G. G., & Suria, H. (2010) · The AAPS Journal · doi:10.1208/s12248-009-9157-5 · Cited by 305
Sand, K. M. K., Bern, M., Nilsen, J., Noordzij, H. T., Sandlie, I., & Andersen, J. T. (2015) · Frontiers in Immunology · doi:10.3389/fimmu.2014.00682 · Cited by 304
Cited by
Vascularized organoids on a chip: strategies for engineering organoids with functional vasculature
Zhang, S., Wan, Z., & Kamm, R. D. (2021) · Lab on a Chip · doi:10.1039/d0lc01186j · Cited by 316
Self-citationEngineered human blood–brain barrier microfluidic model for vascular permeability analyses
Hajal, C., Offeddu, G. S., Shin, Y., Zhang, S., Morozova, O., Hickman, D., Knutson, C. G., & Kamm, R. D. (2022) · Nature Protocols · doi:10.1038/s41596-021-00635-w · Cited by 257
Self-citationFrom Arteries to Capillaries: Approaches to Engineering Human Vasculature
Fleischer, S., Tavakol, D. N., & Vunjak‐Novakovic, G. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910811 · Cited by 195
The CCL2-CCR2 astrocyte-cancer cell axis in tumor extravasation at the brain
Hajal, C., Shin, Y., Li, L., Serrano, J. C., Jacks, T., & Kamm, R. D. (2021) · Science Advances · doi:10.1126/sciadv.abg8139 · Cited by 69
Self-citationHajal, C., Ibrahim, L., Serrano, J. C., Offeddu, G. S., & Kamm, R. D. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120470 · Cited by 68
Self-citation
Metadata
- Authors
- Offeddu, G. S., Haase, K., Gillrie, M. R., Li, R., Morozova, O., Hickman, D., Knutson, C. G., & Kamm, R. D.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 212
- Pages
- 115-125
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2945792826
- Cited by
- 109
- References
- 6
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.