The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Fe3O4 magnetic nanoparticles/reduced graphene oxide nanosheets as a novel electrochemical and bioeletrochemical sensing platform
Open accessAbstract
We have developed Fe3O4 magnetic nanoparticles/reduced graphene oxide nanosheets modified glassy carbon (Fe3O4/r-GO/GC) electrode as a novel system for the preparation of electrochemical sensing platform. Decorating Fe3O4 nanoparticles on graphene sheets was performed via a facile one-step chemical reaction strategy, where the reduction of GO and the in-situ generation of Fe3O4 nanoparticles occurred simultaneously. Characterization of as-made nanocomposite using X-ray diffraction (XRD), transmission electron microscopy (TEM) and alternative gradient force magnetometry (AGFM) clearly demonstrate the successful attachment of monodisperse Fe3O4 nanoparticles to graphene sheets. Electrochemical studies revealed that the Fe3O4/r-GO/GC electrode possess excellent electrocatalytic activities toward the low potential oxidation of NADH (0.05 V vs. Ag/AgCl) as well as the catalytic reduction of O2 and H2O2 at reduced overpotentials. Via immobilization of lactate dehydrogenase (LDH) as a model dehydrogenase enzyme onto the Fe3O4/r-GO/GC electrode surface, the ability of modified electrode for biosensing lactate was demonstrated. In addition, using differential pulse voltammetry (DPV) to investigate the electrochemical oxidation behavior of ascorbic acid (AA), dopamine (DA) and uric acid (UA) at Fe3O4/r-GO/GC electrode, the high electrocatalytic activity of the modified electrode toward simultaneous detection of these compounds was indicated. Finally, based on the strong electrocatalytic action of Fe3O4/r-GO/GC electrode toward both oxidation and reduction of nitrite, a sensitive amperometric sensor for nitrite determination was proposed. The Fe3O4/r-GO hybrid presented here showing favorable electrochemical features may hold great promise to the development of electrochemical sensors, molecular bioelectronic devices, biosensors and biofuel cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of Graphitic Oxide
Hummers, W. S., & Offeman, R. E. (1958) · Journal of the American Chemical Society · doi:10.1021/ja01539a017 · Cited by 29,920
Processable aqueous dispersions of graphene nanosheets
Li, D., Müller, M. B., Gilje, S., Kaner, R. B., & Wallace, G. G. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2007.451 · Cited by 9,114
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Transparent, Conductive Graphene Electrodes for Dye-Sensitized Solar Cells
Wang, X., Zhi, L., & Müllen, K. (2008) · Nano Letters · doi:10.1021/nl072838r · Cited by 4,467
Preparation of aqueous magnetic liquids in alkaline and acidic media
Massart, R. (1981) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1981.1061188 · Cited by 2,817
Water-Dispersible Magnetite-Reduced Graphene Oxide Composites for Arsenic Removal
Chandra, V., Park, J., Chun, Y., Lee, J. W., Hwang, I.-C., & Kim, K. S. (2010) · ACS Nano · doi:10.1021/nn1008897 · Cited by 1,997
Electrochemical Sensing and Biosensing Platform Based on Chemically Reduced Graphene Oxide
Zhou, M., Zhai, Y., & Dong, S. (2009) · Analytical Chemistry · doi:10.1021/ac900136z · Cited by 1,706
Exfoliated Graphene Separated by Platinum Nanoparticles
Si, Y., & Samulski, E. T. (2008) · Chemistry of Materials · doi:10.1021/cm801356a · Cited by 1,126
Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing
Shan, C., Yang, H., Han, D., Zhang, Q., Ivaska, A., & Niu, L. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.024 · Cited by 788
Zhu, Y., Stoller, M. D., Cai, W., Velamakanni, A., Piner, R. D., Chen, D., & Ruoff, R. S. (2010) · ACS Nano · doi:10.1021/nn901689k · Cited by 681
Electrochemistry of graphene: new horizons for sensing and energy storage
Pumera, M. (2009) · The Chemical Record · doi:10.1002/tcr.200900008 · Cited by 636
Synthesis and characterisation of hydrophilic and organophilic graphene nanosheets
Wang, G., Shen, X., Wang, B., Yao, J., & Park, J. (2009) · Carbon · doi:10.1016/j.carbon.2009.01.027 · Cited by 594
Sun, C.-L., Lee, H.-H., Yang, J.-M., & Wu, C.-C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.023 · Cited by 524
THE JOURNAL OF PHYSICAL CHEMISTRY
(1922) · Science · doi:10.1126/science.56.1446.304 · Cited by 466
The attachment of Fe3O4 nanoparticles to graphene oxide by covalent bonding
He, F., Fan, J., Ma, D., Zhang, L., Leung, C., & Chan, H. L. (2010) · Carbon · doi:10.1016/j.carbon.2010.04.052 · Cited by 462
He, H., & Gao, C. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100673g · Cited by 409
A novel hydrogen peroxide biosensor based on Au–graphene–HRP–chitosan biocomposites
Zhou, K., Zhu, Y., Yang, X., Luo, J., Li, C., & Luan, S. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.01.035 · Cited by 378
Cong, H., He, J., Lu, Y., & Yu, S. (2010) · Small · doi:10.1002/smll.200901360 · Cited by 355
Liu, S., Tian, J., Wang, L., & Sun, X. (2011) · Carbon · doi:10.1016/j.carbon.2011.03.036 · Cited by 318
Mani, V., Periasamy, A. P., & Chen, S. (2012) · Electrochemistry Communications · doi:10.1016/j.elecom.2012.02.009 · Cited by 305
Qian, L., & Yang, X. (2006) · Talanta · doi:10.1016/j.talanta.2005.05.030 · Cited by 240
A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide
Guascito, M. R., Filippo, E., Malitesta, C., Manno, D., Serra, A., & Turco, A. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.07.048 · Cited by 213
Teymourian, H., Salimi, A., & Hallaj, R. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.031 · Cited by 152
Self-citationNavaee, A., Salimi, A., & Teymourian, H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.018 · Cited by 144
Self-citationYe, Y., Kong, T., Yu, X., Wu, Y., Zhang, K., & Wang, X. (2011) · Talanta · doi:10.1016/j.talanta.2011.12.054 · Cited by 143
Yue, Y., Hu, G., Zheng, M., Guo, Y. A., Cao, J., & Shao, S. (2011) · Carbon · doi:10.1016/j.carbon.2011.08.013 · Cited by 121
Modified electrodes for NADH oxidation and dehydrogenase-based biosensors
Bartlett, P. N., Simon, E., & Toh, C.-S. (2002) · Bioelectrochemistry · doi:10.1016/s1567-5394(02)00047-6 · Cited by 68
Tang, D., Tang, J., Li, Q., Liu, B., Yang, H., & Chen, G. (2011) · RSC Advances · doi:10.1039/c1ra00114k · Cited by 17
Cited by
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Metal oxide nanoparticles in electrochemical sensing and biosensing: a review
George, J. M., Antony, A., & Mathew, B. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2894-3 · Cited by 580
Graphene based sensors and biosensors
Justino, C. I. L., Gomes, A. R., Freitas, A. C., Duarte, A. C., & Rocha-Santos, T. A. P. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.003 · Cited by 574
Metadata
- Authors
- Teymourian, H., Salimi, A., & Khezrian, S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 49
- Pages
- 1-8
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1985788901
- Cited by
- 537
- References
- 28
- FWCI
- 33.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.