The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Development of an ultrasensitive aptasensor for the detection of aflatoxin B1
Open accessAbstract
Contamination of feed and food by aflatoxin B1 (AFB1), one of the most toxic of the mycotoxins, is a global concern. To prevent food safety scares, and avoid subsequent economic losses due to the recall of contaminated items, methods for the rapid, sensitive and specific detection of AFB1 at trace levels are much in demand. In this work, a simple, ultrasensitive, and reliable aptasensor is described for the detection of AFB1. An AFB1 aptamer was used as a molecular recognition probe, while its complementary DNA played a role as a signal generator for amplification by real-time quantitative polymerase chain reaction (PCR). Under optimal conditions, a wide linear detection range (5.0 × 10(-5) to 5.0 ng mL(-1)) was achieved, with a high sensitivity (limit of detection (LOD)=25 fg mL(-1)). In addition, the proposed aptasensor exhibited excellent specificity for AFB1 compared with eight other mycotoxins, with no obvious Ct value change. This aptasensor can also be used in quantifying AFB1 levels in Chinese wild rye hay samples and infant rice cereal samples, demonstrating satisfactory recoveries in the range of 88-127% and 94-119%, respectively. This detection technique has a significant potential for high-throughput, quantitative determination of mycotoxin levels in a large range of feeds and foods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Cited by
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Zhang, H., Ma, X., Liu, Y., Duan, N., Wu, S., Wang, Z., & Xu, B. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.033 · Cited by 297
The application of nanoparticles in point-of-care testing (POCT) immunoassays
Hou, F., Sun, S., Abdullah, S. W., Tang, Y., Li, X., & Guo, H. (2023) · Analytical Methods · doi:10.1039/d3ay00182b · Cited by 61
Metadata
- Authors
- Guo, X., Wen, F., Zheng, N., Luo, Q., Wang, H., Wang, H., Li, S., & Wang, J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 56
- Pages
- 340-344
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W1965590158
- Cited by
- 159
- References
- 1
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of an ultrasensitive aptasensor for the detection of aflatoxin B1. https://app.cochat.ai/papers/10.1016/j.bios.2014.01.045
- The paper
- Guo, X., Wen, F., Zheng, N., Luo, Q., Wang, H., Wang, H., Li, S., & Wang, J. (2014). Development of an ultrasensitive aptasensor for the detection of aflatoxin B1. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2014.01.045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.