The DOI matches its Crossref record.
Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device
Open accessAbstract
We present a new, power-free and flexible detection system named MCFphone for portable colorimetric and fluorescence quantitative sandwich immunoassay detection of prostate specific antigen (PSA). The MCFphone is composed by a smartphone integrated with a magnifying lens, a simple light source and a miniaturised immunoassay platform, the Microcapillary Film (MCF). The excellent transparency and flat geometry of fluoropolymer MCF allowed quantitation of PSA in the range 0.9 to 60 ng/ml with<7% precision in 13 min using enzymatic amplification and a chromogenic substrate. The lower limit of detection was further improved from 0.4 to 0.08 ng/ml in whole blood samples with the use of a fluorescence substrate. The MCFphone has shown capable of performing rapid (13 to 22 min total assay time) colorimetric quantitative and highly sensitive fluorescence tests with good %Recovery, which represents a major step in the integration of a new generation of inexpensive and portable microfluidic devices with commercial immunoassay reagents and off-the-shelf smartphone technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Point-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Portable biosensing devices for point-of-care diagnostics: Recent developments and applications
Zarei, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.001 · Cited by 326
Biomarker detection technologies and future directions
Nimse, S. B., Sonawane, M. D., Song, K.-S., & Kim, T. (2016) · The Analyst · doi:10.1039/c5an01790d · Cited by 275
Metadata
- Authors
- Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-08
- Volume
- 70
- Pages
- 5-14
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2048735596
- Cited by
- 225
- References
- 0
- FWCI
- 14.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device. https://app.cochat.ai/papers/10.1016/j.bios.2015.03.006
- The paper
- Barbosa, A. I., Gehlot, P., Sidapra, K., Edwards, A. D., & Reis, N. M. (2015). Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2015.03.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.