The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly sensitive detection of urinary protein variations using tilted fiber grating sensors with plasmonic nanocoatings
Open accessAbstract
Surface plasmon resonance (SPR) optical fiber biosensors can be used as a cost-effective and relatively simple-to-implement alternative to well established bulky prism configurations for high sensitivity biological sample measurements. The miniaturized size and remote operation ability offer them a multitude of opportunities for single-point sensing in hard-to-reach spaces, even possibly in vivo. The biosensor configuration reported in this work uses a tilted fiber Bragg grating (TFBG) in a commercial single mode fiber coated with a nanometer scale silver film. The key point is that by reducing the silver film thickness to around 20-30 nm (rather than 50 nm for optimal SPR excitation), different modes of the TFBG spectrum present very high but opposite sensitivities to refractive index (RI) changes around the TFBG. Experimental results obtained with the coated TFBG embedded inside a microfluidic channel show an amplitude sensitivity greater than 8000 dB/RIU (Refractive Index Unit) and a limit of detection of 10(-5)RIU. Using this device, the effect of different concentrations of protein in rat urine was clearly differentiated between healthy samples, nephropatic samples and samples from individuals under treatment, with a protein concentration sensitivity of 5.5 dB/(mg/ml) and a limit of detection of 1.5 × 10(-3)mg/ml. Those results show a clear relationship between protein outflow and variations in the RI of the urine samples between 1.3400 and 1.3408, pointing the way to the evaluation and development of new drugs for nephropathy treatments. The integration of TFBGs with microfluidic channels enables precise measurement control over samples with sub-microliter volumes and does not require accurate temperature control because of the elimination of the temperature cross-sensitivity inherent in TFBG devices. Integration of the TFBG with a hypodermic needle on the other hand would allow similar measurements in vivo. The proposed optical fiber/microfluidic plasmonic biosensor represents an appealing solution for rapid, low consumption and highly sensitive detection of analytes at low concentrations in medicine as well as in chemical and environmental monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
Cited by
Xu, Y., Bai, P., Zhou, X., Akimov, Y., Png, C. E., Ang, L., Knoll, W., & Wu, L. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801433 · Cited by 519
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Metadata
- Authors
- Guo, T., Liu, F., Liang, X., Qiu, X., Huang, Y., Xie, C., Xu, P., Mao, W., Guan, B.-O., & Albert, J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2016-04
- Volume
- 78
- Pages
- 221-228
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2216683958
- Cited by
- 182
- References
- 2
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.