Cited by 55Plasmonic and Surface Plasmon ResearchGold and Silver Nanoparticles Synthesis and ApplicationsElectrochemical sensors and biosensors

Label-free detection of 3-nitro-l-tyrosine with nickel-doped graphene localized surface plasmon resonance biosensor

Ng, Siu Pang, Qiu, Guangyu, Ding, Ning, Lu, Xiaoqing, Wu, Chi-Man Lawrence·2017·Biosensors and Bioelectronics

Abstract

3-nitro-l-tyrosine (3-NT) is believed to be a biomarker of neurodegenerative diseases and metal doped graphene possess exceptionally high binding energy of 3-NT with metal-nitro chemisorption. Here we report a novel label-free detection scheme of 3-NT via nickel-doped graphene (NDG) as the functionalized receptor on our phase detecting localized surface plasmon resonance (LSPR) biosensor. When compared with reported 3-NT immunoassay with enzyme-linked immunosorbent assay (ELISA), our NDG-LSPR platform offers two advantages i.e. 1) label-free and 2) capture of 3-NT by direct chemisorption. Our limit of detection for 3-NT in PBS was found to be 0.13pg/ml and the linear dynamic range of response was from 0.5pg/ml to 1ng/ml, i.e. four orders of magnitude. The specificity of our NDG receptor to 3-NT was also verified with l-tyrosine of equivalent concentrations in PBS and diluted human serum, for which the NDG receptor shows negligible responses. In addition, the adsorption of 3-NT and l-tyrosine to the NDG receptor were also investigated by atomic force microscopy and further verified by surface enhanced Raman spectroscopy. Therefore, our NDG-LSPR biosensor competes favorably against ELISA and we believe it should be an attractive and economical solution to early diagnostic of 3-NT related disorders for clinical applications.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2016.04.017

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In 2016, Ng et al. demonstrated a novel detection scheme of 3-NT using a nickel-doped graphene synthetic receptor combined with a localized surface plasmon resonance biosensor.

    “In 2016, Ng et al. demonstrated a novel detection scheme of 3-NT by using a nickel-doped graphene synthetic receptor combined with a localized surface plasmon resonance biosensor”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ng, S. P., Qiu, G., Ding, N., Lu, X., & Wu, C.-M. L.
Affiliations
City University of Hong Kong (HK)
Corresponding author
Wu, Chi-Man Lawrence
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2017-03
Volume
89
Issue
Pt 1
Pages
468-476
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2326867847
Cited by
55
References
1
Citations by year
2026: 2 · 2025: 3 · 2024: 4 · 2023: 6 · 2022: 8 · 2021: 9 · 2020: 6 · 2019: 7 · 2018: 5 · 2017: 4 · 2016: 1
FWCI
2.73
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • City University of Hong Kong (Grant No. 9667110)
  • National Natural Science Foundation of China (Grant No. 11404192)
  • Shandong Province Special Grant for High-Level Overseas Talents (tshw20120745)
  • Outstanding Young and Middle-aged Scientists of Shandong Province (BS2014CL002)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
nitrotyrosine, label-free detection, chemisorption, neurodegenerative disease biomarkers, metal-doped graphene, tyrosine, human serum, early diagnosis
MeSH terms
Enzyme-Linked Immunosorbent Assay, Gold, Graphite, Humans, Nickel, Tyrosine, Biomarkers, Neurodegenerative Diseases, Surface Plasmon Resonance, Nanostructures, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review