The DOI matches its Crossref record.
Versatility of a localized surface plasmon resonance-based gold nanoparticle-alloyed quantum dot nanobiosensor for immunofluorescence detection of viruses
Open accessAbstract
Flu infection, caused by the influenza virus, constitutes a serious threat to human lives worldwide. A rapid, sensitive and specific diagnosis is urgently needed for point-of-care treatment and to control the rapid spread of this disease. In this study, an ultrasensitive, rapid and specific localized surface plasmon resonance (LSPR)-induced immunofluorescence nanobiosensor has been developed for the influenza virus based on a gold nanoparticle (AuNP)-induced quantum dot (QD) fluorescence signal. Alloyed quaternary CdSeTeS QDs were synthesized via the hot-injection organometallic route and were subsequently capped with l-cysteine via a ligand exchange reaction. AuNPs were synthesized in HEPES buffer and thiolated with l-cysteine. The concept of the biosensor involves the conjugation of anti-neuraminidase (NA) antibody (anti-NA Ab) to thiolated AuNPs and the conjugation of anti-hemagglutinin (HA) antibody (anti-HA Ab) to alloyed quaternary l-cysteine-capped CdSeTeS QDs. Interaction of the antigens displaying on the surface of the influenza virus target with anti-NA Ab-conjugated AuNPs and anti-HA Ab-conjugated QDs induces an LSPR signal from adjacent AuNPs to trigger fluorescence-enhancement changes in the QDs in proportion to the concentration of the target virus. The detection limit for influenza H1N1 virus was 0.03pg/mL in deionized water and 0.4pg/mL in human serum; while, for the clinically isolated H3N2, the detection limit was 10PFU/mL. The detection of influenza virus H1N1 was accomplished with high sensitivity. The versatility of the biosensor was demonstrated for the detection of clinically isolated influenza virus H3N2 and norovirus-like particles (NoV-LPs).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A comprehensive review on plasmonic-based biosensors used in viral diagnostics
Shrivastav, A. M., Cvelbar, U., & Abdulhalim, I. (2021) · Communications Biology · doi:10.1038/s42003-020-01615-8 · Cited by 495
Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Heidt, B., Siqueira, W., Eersels, K., Diliën, H., van Grinsven, B., Fujiwara, R., & Cleij, T. (2020) · Biosensors · doi:10.3390/bios10100133 · Cited by 260
Ganganboina, A. B., Chowdhury, A. D., Khoris, I. M., Nasrin, F., Takemura, K., Hara, T., Abe, F., Suzuki, T., & Park, E. Y. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112169 · Cited by 68
Self-citation
Metadata
- Authors
- Takemura, K., Adegoke, O., Takahashi, N., Kato, T., Li, T.-C., Kitamoto, N., Tanaka, T., Suzuki, T., & Park, E. Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 89
- Issue
- Pt 2
- Pages
- 998-1005
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2532043364
- Cited by
- 164
- References
- 0
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Versatility of a localized surface plasmon resonance-based gold nanoparticle-alloyed quantum dot nanobiosensor for immunofluorescence detection of viruses. https://app.cochat.ai/papers/10.1016/j.bios.2016.10.045
- The paper
- Takemura, K., Adegoke, O., Takahashi, N., Kato, T., Li, T.-C., Kitamoto, N., Tanaka, T., Suzuki, T., & Park, E. Y. (2017). Versatility of a localized surface plasmon resonance-based gold nanoparticle-alloyed quantum dot nanobiosensor for immunofluorescence detection of viruses. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2016.10.045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.