A highly specific and ultrasensitive near-infrared fluorescent probe for imaging basal hypochlorite in the mitochondria of living cells
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The development of highly specific and ultrasensitive fluorescent probes for tracking basal mitochondrial hypochlorite is very important to unravel its diverse cellular functions in the mitochondria of living cells. In this paper, we have developed a water-soluble, mitochondria-targeted near-infrared fluorescent probe NB-OCl for selectively measuring OCl- in the presence of higher concentration (500 μM) other biologically important substances. Surprisingly, the obtained results demonstrated that probe NB-OCl could sensitively determine OCl- in the range of 0-200 pM with the detection limit of 10.8 pM. To the best of our knowledge, NB-OCl is the first fluorescent probe for the specific determination of OCl- at the picomolar level. Moreover, probe NB-OCl exhibits a fast response for OCl- (< 5 s), which would be in favor of tracking the highly reactive and short-lived OCl- in the living systems. The preeminent recognition properties of probe NB-OCl enable its applications in the monitoring of basal OCl- and the fluctuations of endogenous/exogenous OCl- levels in the mitochondria of living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How mitochondria produce reactive oxygen species
Murphy, M. P. (2009) · Biochemical Journal · doi:10.1042/bj20081386 · Cited by 8,207
Tlr signalling augments macrophage bactericidal activity through mitochondrial ros
West, A. P., Brodsky, I. E., Rahner, C., Woo, D. K., Erdjument-Bromage, H., Tempst, P., Walsh, M. C., Choi, Y., Shadel, G. S., & Ghosh, S. (2011) · Nature · doi:10.1038/nature09973 · Cited by 1,659
Biological reactivity and biomarkers of the neutrophil oxidant, hypochlorous acid
Winterbourn, C. C. (2002) · Toxicology · doi:10.1016/s0300-483x(02)00286-x · Cited by 247
Metadata
- Authors
- Zhu, B., Wu, L., Zhang, M., Wang, Y., Liu, C., Wang, Z., Duan, Q., & Jia, P.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 107
- Pages
- 218-223
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2793982406
- Cited by
- 164
- References
- 3
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A highly specific and ultrasensitive near-infrared fluorescent probe for imaging basal hypochlorite in the mitochondria of living cells. https://app.cochat.ai/papers/10.1016/j.bios.2018.02.023
- The paper
- Zhu, B., Wu, L., Zhang, M., Wang, Y., Liu, C., Wang, Z., Duan, Q., & Jia, P. (2018). A highly specific and ultrasensitive near-infrared fluorescent probe for imaging basal hypochlorite in the mitochondria of living cells. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.02.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.