Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A novel electrochemical sensor based on silver/halloysite nanotube/molybdenum disulfide nanocomposite for efficient nitrite sensing

Ghanei-Motlagh, Masoud, Taher, Mohammad Ali · 2018 · Biosensors and Bioelectronics

Abstract

In the present study, the silver/halloysite nanotube/molybdenum disulfide (Ag/HNT/MoS2) nanocomposite was successfully synthesized. For this purpose, the lumen of HNTs was firstly modified by silver to generate Ag nanorods via chemical process and then the MoS2 layers deposited on the Ag/HNT nanocomposite by hydrothermal method. The characterization of Ag/HNT/MoS2 nanocomposite were investigated by field emission scanning electron microscopy (FE-SEM), Fourier transform infrared (FT-IR) spectroscopy, transmission electron microscopy (TEM), X-ray photoelectron spectra (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analyses. The nanocomposite modified carbon paste electrode (CPE) was applied for the electrocatalytic detection of nitrite in aqueous solutions. It was demonstrated that the treatment of HNTs with Ag and MoS2 materials enhanced the catalytic performance of modified CPE. At optimal experimental conditions, the designed sensor displayed remarkable sensing ability toward nitrite oxidation, offering a good linearity from 2 to 425 µM. The limit of detection (LOD) of the proposed strategy was estimated to be 0.7 µM based S/N = 3. The good reproducibility, acceptable stability, fast response time and anti-interference performance of the proposed assay suggests that the modified CPE has great potential working as a nitrite electrochemical sensor for environmental applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2018.02.057

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 222

Metadata

Authors
Ghanei-Motlagh, M., & Taher, M. A.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2018-06
Volume
109
Pages
279-285
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2791615464
Cited by
222
References
1
FWCI
10.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.