Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Graphene nanocomposites modified electrochemical aptamer sensor for rapid and highly sensitive detection of prostate specific antigen

Open access
Wei, Bo, Mao, Kang, Liu, Na, Zhang, Man, Yang, Zhugen·2018·Biosensors and Bioelectronics

Abstract

Prostate specific antigen (PSA) is a widely used marker for the diagnosis of prostate cancer, and the increasing attention has been attracted on the development of rapid assay using biosensing technology. However, it remains challenging for the sensitive and selective detection of PSA in clinical samples. Here, we report a label-free microfluidic paper-based analytical device for highly sensitive electrochemical detection of PSA. The paper device was fabricated with wax printing to generate hydrophobic and hydrophilic layers for the construction of microfluidic channel, followed by screen-printing of three electrodes including working, counter and reference electrode. Gold nanoparticles (AuNPs)/reduced graphene oxide (rGO)/thionine (THI) nano composites were synthesized and characterized, which were coated onto working electrodes for the immobilization of DNA aptamer probe. THI servers as the electrochemical mediator to transduce the biological recognition between DNA aptamer and PSA, and the excellent conductivity of AuNPs and rGO also play a significant role of electron transfer, leading to a sensitive detection for PSA, able to detect PSA as low as 10 pg mL −1 , with a linear range from 0.05 to 200 ng mL −1 . We demonstrated that our electrochemical sensor for the detection of clinical serum samples, indicating that our sensor would provide a new platform for low cost, sensitive and point-of-care diagnosis of prostate cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2018.08.067

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 189

Metadata

Authors
Wei, B., Mao, K., Liu, N., Zhang, M., & Yang, Z.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2018-12
Volume
121
Pages
41-46
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2889084081
Cited by
189
References
1
FWCI
6.12
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Graphene nanocomposites modified electrochemical aptamer sensor for rapid and highly sensitive detection of prostate specific antigen. https://app.cochat.ai/papers/10.1016/j.bios.2018.08.067
The paper
Wei, B., Mao, K., Liu, N., Zhang, M., & Yang, Z. (2018). Graphene nanocomposites modified electrochemical aptamer sensor for rapid and highly sensitive detection of prostate specific antigen. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.08.067

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.