The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biofunctionalized two-dimensional Ti3C2 MXenes for ultrasensitive detection of cancer biomarker
Open accessAbstract
In this work, ultrathin Ti3C2-MXene nanosheets were synthesized by minimally intensive layer delamination methods, and uniformly functionalized with aminosilane (f-Ti3C2-MXene) to provide a covalent binding for the immobilized bio-receptor (anti-CEA) for label free, ultrasensitive detection of cancer biomarker (carcinoembryonic antigen, CEA). The effect of different redox probes on the electrochemical behavior of f-Ti3C2-MXene was investigated and found that hexaammineruthenium ([Ru(NH3)6]3+) is the preferable redox probe for biosensing. The fabricated biofunctionalized Ti3C2-MXene exhibits a linear detection range of 0.0001-2000 ng mL-1 with sensitivity of 37.9 µA ng-1 mL cm-2 per decade. The wider linear detection range of our f-Ti3C2-MXene is not only higher than previously reported pristine 2D nanomaterials, but is even comparable to other hybrid 2D nanomaterials. We believe that this work opens a new window for development of MXene-based highly sensitive DNA, aptamer, enzyme, antibody, and cell based biosensors, and could be further used in drug delivery application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Cited by
A Review on MXene Synthesis, Stability, and Photocatalytic Applications
Murali, G., Reddy Modigunta, J. K., Park, Y. H., Lee, J.-H., Rawal, J., Lee, S.-Y., In, I., & Park, S.-J. (2022) · ACS Nano · doi:10.1021/acsnano.2c04750 · Cited by 668
Recent progress and advances in the environmental applications of MXene related materials
Chen, J., Huang, Q., Huang, H., Mao, L., Liu, M., Zhang, X., & Wei, Y. (2020) · Nanoscale · doi:10.1039/c9nr08542d · Cited by 298
Surface Terminations of MXene: Synthesis, Characterization, and Properties
Tang, M., Li, J., Wang, Y., Han, W., Xu, S., Lu, M., Zhang, W., & Li, H. (2022) · Symmetry · doi:10.3390/sym14112232 · Cited by 279
Ti3C2 2D MXene: Recent Progress and Perspectives in Photocatalysis
Tang, R., Xiong, S., Gong, D., Deng, Y., Wang, Y., Su, L., Ding, C., Yang, L., & Liao, C. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c12905 · Cited by 259
Zhao, F., Yao, Y., Jiang, C., Shao, Y., Barceló, D., Ying, Y., & Ping, J. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121358 · Cited by 253
Metadata
- Authors
- Kumar, S., Lei, Y., Alshareef, N. H., Quevedo-Lopez, M. A., & Salama, K. N.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 121
- Pages
- 243-249
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2889373623
- Cited by
- 463
- References
- 1
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biofunctionalized two-dimensional Ti3C2 MXenes for ultrasensitive detection of cancer biomarker. https://app.cochat.ai/papers/10.1016/j.bios.2018.08.076
- The paper
- Kumar, S., Lei, Y., Alshareef, N. H., Quevedo-Lopez, M. A., & Salama, K. N. (2018). Biofunctionalized two-dimensional Ti3C2 MXenes for ultrasensitive detection of cancer biomarker. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.08.076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.