The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode
Abstract
Determination of hepatotoxic drugs is critical for both clinical diagnosis and quantity control of their pharmaceutical formulations. In this work, a facile and sensitive sensor based on MXene modified screen-printed electrode (MXene/SPE) has been developed for detection of acetaminophen (ACOP) and isoniazid (INZ), which are two commonly used drugs but might induce liver damage in certain circumstances. MXene showed excellent electrocatalytic activity toward the oxidation of ACOP and INZ compared with bare SPE in 0.1 M H2SO4, and the separated oxidation peak potentials ensured simultaneous detection of the targets with wide linear ranges from 0.25 to 2000 μM for ACOP and 0.1-4.6 mM for INZ. The detection limits of ACOP and INZ were 0.048 μM and 0.064 mM, respectively. (S/N = 3). MXene/SPE exhibits good stability, reproducibility and repeatability, and the method has been successfully applied for detection of ACOP and INZ in their pharmaceutical and biological samples with satisfactory recovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2D MXenes: A New Family of Promising Catalysts for the Hydrogen Evolution Reaction
Gao, G., O’Mullane, A. P., & Du, A. (2017) · ACS Catalysis · doi:10.1021/acscatal.6b02754 · Cited by 1,153
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Sensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
Chaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
Deshmukh, K., Kovářík, T., & Khadheer Pasha, S. K. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213514 · Cited by 282
Recent Advances in Emerging 2D Material‐Based Gas Sensors: Potential in Disease Diagnosis
Zhang, L., Khan, K., Zou, J., Zhang, H., & Li, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901329 · Cited by 281
Self-citation
Metadata
- Authors
- Zhang, Y., Jiang, X., Zhang, J., Zhang, H., & Li, Y.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 130
- Pages
- 315-321
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2912954966
- Cited by
- 289
- References
- 1
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode. https://app.cochat.ai/papers/10.1016/j.bios.2019.01.043
- The paper
- Zhang, Y., Jiang, X., Zhang, J., Zhang, H., & Li, Y. (2019). Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.01.043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.