The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Label-free electrochemical DNA biosensor for zika virus identification
Open accessAbstract
Seventy years after its discovery, the zika virus emerged in Brazil and spread rapidly throughout the Americas, bringing unusual complications such as microcephaly. The World Health Organization classifies zika as the most harmful viral disease today and considers the development of new diagnostic methods for zika and related diseases, such as dengue, urgent. Although there are tests to identify both infections, current diagnostic methods are slow, nonspecific, and costly. This study describes an impedimetric electrochemical DNA biosensor for label-free detection of zika virus. Disposable electrodes were fabricated by thermal evaporation on polyethylene terephthalate substrates covered with a nanometric gold layer manufactured in three-contact configurations. The disposable, evaporated electrodes were morphologically characterized by atomic force microscopy and scanning electron microscopy. The electrode surface was characterized by electroanalytical techniques. Genetic sequences of primers and complementary capture probes were designed based on analysis of the zika and dengue virus genomes. The biosensor used a three-contact electrode to identify DNA sequences in a drop of sample, and for detection of zika virus sequences, it allowed for direct reading of the hybridization event without labeling on disposable electrodes and with a 1.5 h response time. In this system, impedance measurements indicated a limit of detection of 25.0 ± 1.7 nM. The developed biosensors showed selectivity for zika in the synthetic DNA assays, and therefore, are promising for clinical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The global distribution and burden of dengue
Bhatt, S., Gething, P. W., Brady, O. J., Messina, J. P., Farlow, A. W., Moyes, C. L., Drake, J. M., Brownstein, J. S., Hoen, A. G., Sankoh, O., et al. (2013) · Nature · doi:10.1038/nature12060 · Cited by 10,037
Cited by
Electrochemical Sensors and Their Applications: A Review
Baranwal, J., Barse, B., Gatto, G., Broncova, G., & Kumar, A. (2022) · Chemosensors · doi:10.3390/chemosensors10090363 · Cited by 978
Detection of COVID-19: A review of the current literature and future perspectives
Ji, T., Liu, Z., Wang, G., Guo, X., Akbar khan, S., Lai, C., Chen, H., Huang, S., Xia, S., Chen, B., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112455 · Cited by 383
Jain, S., Nehra, M., Kumar, R., Dilbaghi, N., Hu, T., Kumar, S., Kaushik, A., & Li, C.-Z. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113074 · Cited by 357
Ganganboina, A. B., Chowdhury, A. D., Khoris, I. M., Nasrin, F., Takemura, K., Hara, T., Abe, F., Suzuki, T., & Park, E. Y. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112169 · Cited by 68
Metadata
- Authors
- Faria, H. A. M., & Zucolotto, V.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 131
- Pages
- 149-155
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2917921672
- Cited by
- 165
- References
- 1
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.