Cited by 153Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAnalytical Chemistry and Sensors

Wearable multiplexed biosensor system toward continuous monitoring of metabolites

Open access
Yokus, Murat A., Songkakul, Tanner, Pozdin, Vladimir A., Bozkurt, Alper, Daniele, Michael A.·2020·Biosensors and Bioelectronics

Abstract

Comprehensive metabolic panels are the most reliable and common methods for monitoring general physiology in clinical healthcare. Translation of this clinical practice to personal health and wellness tracking requires reliable, non-invasive, miniaturized, ambulatory, and inexpensive systems for continuous measurement of biochemical analytes. We report the design and characterization of a wearable system with a flexible sensor array for non-invasive and continuous monitoring of human biochemistry. The system includes signal conditioning, processing, and transmission parts for continuous measurement of glucose, lactate, pH, and temperature. The system can operate three discrete electrochemical cells. The system draws 15 mA under continuous operation when powered by a 3.7 V 150 mAh battery. The analog front-end of the electrochemical cells has four potentiostats and three multiplexers for multiplexed and parallel readout from twelve working electrodes. Utilization of redundant working electrodes improves the measurement accuracy of sensors by averaging chronoamperometric responses across the array. The operation of the system is demonstrated in vitro by simultaneous measurement of glucose and lactate, pH, and skin temperature. In benchtop measurements, the sensors are shown to have sensitivities of 26.31 μA mM-1·cm-2 for glucose, 1.49 μA mM-1·cm-2 for lactate, 54 mV·pH-1 for pH, and 0.002 °C-1 for temperature. With the custom wearable system, these values were 0.84 ± 0.03 mV μM-1·cm-2 or glucose, 31.87 ± 9.03 mV mM-1·cm-2 for lactate, 57.18 ± 1.43 mV·pH-1 for pH, and 63.4 μV·°C-1 for temperature. This miniaturized wearable system enables future evaluation of temporal changes of the sweat biomarkers.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112038

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Most wearable sweat sensors are unable to draw low volumes of resting sweat rapidly into the device, limiting real-time assessment.

    “They are unable to draw low volumes of resting sweat rapidly into the device, limiting real-time assessment.”
  • Most wearable sweat sensors have focused on exercise, thermal, or chemically stimulated sweat produced at rates of 10's or 100's of nL min−1 cm−2 or higher.

    “For this reason, most wearable sweat sensors have focused on exercise, thermal, or chemically stimulated sweat produced at rates of 10’s or 100’s of nL min−1 cm−2 or higher10–23.”

The citation lists haven’t been fetched yet

References 70 · Cited by 153

Authors
Yokus, M. A., Songkakul, T., Pozdin, V. A., Bozkurt, A., & Daniele, M. A.
Affiliations
  • North Carolina State University (US)
  • University of North Carolina at Chapel Hill (US)
Corresponding author
  • Bozkurt, Alper
  • Daniele, Michael A.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2020-04
Volume
153
Pages
112038
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2999401482
Cited by
153
References
70
Citations by year
2026: 16 · 2025: 20 · 2024: 24 · 2023: 26 · 2022: 23 · 2021: 33 · 2020: 11
FWCI
7.99
Type
journal article
Language
en
Open access
Locations
  • Biosensors and Bioelectronics (acceptedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
wearable biosensors, multiplexed biosensors, flexible sensor array, non-invasive glucose measurement, lactate measurement, pH sensing, skin temperature, sweat biomarkers, potentiostat, chronoamperometry, personal health monitoring
MeSH terms
Wearable Electronic Devices, Dimethylpolysiloxanes, Electrodes, Glucose, Humans, Hydrogen-Ion Concentration, Monitoring, Physiologic, Skin Temperature, Surface Properties, Sweat, Biosensing Techniques, Lactic Acid, Metabolome, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review