The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Recent advances in lab-on-a-chip technologies for viral diagnosis
Open accessAbstract
The global risk of viral disease outbreaks emphasizes the need for rapid, accurate, and sensitive detection techniques to speed up diagnostics allowing early intervention. An emerging field of microfluidics also known as the lab-on-a-chip (LOC) or micro total analysis system includes a wide range of diagnostic devices. This review briefly covers both conventional and microfluidics-based techniques for rapid viral detection. We first describe conventional detection methods such as cell culturing, immunofluorescence or enzyme-linked immunosorbent assay (ELISA), or reverse transcription polymerase chain reaction (RT-PCR). These methods often have limited speed, sensitivity, or specificity and are performed with typically bulky equipment. Here, we discuss some of the LOC technologies that can overcome these demerits, highlighting the latest advances in LOC devices for viral disease diagnosis. We also discuss the fabrication of LOC systems to produce devices for performing either individual steps or virus detection in samples with the sample to answer method. The complete system consists of sample preparation, and ELISA and RT-PCR for viral-antibody and nucleic acid detection, respectively. Finally, we formulate our opinions on these areas for the future development of LOC systems for viral diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Inflammasome inhibition prevents α-synuclein pathology and dopaminergic neurodegeneration in mice
Gordon, R., Albornoz, E. A., Christie, D. C., Langley, M. R., Kumar, V., Mantovani, S., Robertson, A. A. B., Butler, M. S., Rowe, D. B., O’Neill, L. A., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aah4066 · Cited by 897
Plasmon induced thermoelectric effect in graphene
Shautsova, V., Sidiropoulos, T., Xiao, X., Güsken, N. A., Black, N. C. G., Gilbertson, A. M., Giannini, V., Maier, S. A., Cohen, L. F., & Oulton, R. F. (2018) · Nature Communications · doi:10.1038/s41467-018-07508-z · Cited by 710
Futsch, N., Mahieux, R., & Dutartre, H. (2017) · Viruses · doi:10.3390/v10010001 · Cited by 155
Cited by
Detection of COVID-19: A review of the current literature and future perspectives
Ji, T., Liu, Z., Wang, G., Guo, X., Akbar khan, S., Lai, C., Chen, H., Huang, S., Xia, S., Chen, B., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112455 · Cited by 383
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Biosensor and Lab-on-a-chip Biomarker-identifying Technologies for Oral and Periodontal Diseases
Steigmann, L., Maekawa, S., Sima, C., Travan, S., Wang, C.-W., & Giannobile, W. V. (2020) · Frontiers in Pharmacology · doi:10.3389/fphar.2020.588480 · Cited by 77
Metadata
- Authors
- Zhu, H., Fohlerová, Z., Pekárek, J., Basova, E., & Neužil, P.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 153
- Pages
- 112041
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3002683399
- Cited by
- 251
- References
- 4
- FWCI
- 12.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in lab-on-a-chip technologies for viral diagnosis. https://app.cochat.ai/papers/10.1016/j.bios.2020.112041
- The paper
- Zhu, H., Fohlerová, Z., Pekárek, J., Basova, E., & Neužil, P. (2020). Recent advances in lab-on-a-chip technologies for viral diagnosis. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.