The DOI matches its Crossref record; the references it cites are not checked yet.
Guided mode resonance sensor for the parallel detection of multiple protein biomarkers in human urine with high sensitivity
Open accessAbstract
The rising cost of global healthcare provision and new approaches to managing disease are driving the development of low-cost biosensing modalities, such as label-free photonic methods based on dielectric resonances. Here, we use the combined sensing and imaging capability of a guided mode resonance (GMR) sensor to detect multiple biomarkers (troponin, procalcitonin and C-Reactive Protein) in parallel in undiluted urine samples. A key requirement of such a biosensor is the simple and direct functionalization with suitable antibodies to ensure the disease-specific detection of protein biomarkers. Here, antibodies were immobilized using a succinimidyl-[(N-maleimidopropionamido)-hexaethyleneglycol] ester (SM(PEG)6) spacer. The polyethylene glycol (PEG) chemistry enables low detection limits of 10 pg mL-1 or better for all protein biomarkers, while minimizing non-specific binding compared to more commonly used strategies such as (3-Aminopropyl)triethoxysilane (APTES) or dextran. Our approach supports the vision of a simple yet highly sensitive diagnostic platform that could be used for pre-screening patients for a wide range of diseases at point-of-care, thereby relieving the pressure on overstretched healthcare services.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
References 32 · Cited by 61
Research works printed but not linked: 35
- Barnes, 1966, J. Immunol., 96, 854, 10.4049/jimmunol.96.5.854 · DOI
- Cunningham, 2010, J. Assoc. Lab. Autom., 15, 120, 10.1016/j.jala.2009.10.009 · DOI
- Dixit, 2011, Nat. Protoc., 6, 439, 10.1038/nprot.2011.304 · DOI
- Drayton, 2019, Semiconduct. Semimet., 100, 115, 10.1016/bs.semsem.2019.01.002 · DOI
- Eamudomkarn, 2018, PloS One, 13, 10.1371/journal.pone.0192598 · DOI
- Hughes-Jones, 1964, Immunology, 7, 72
- Jönsson, 2008, Lab Chip, 8, 1191, 10.1039/b800297e · DOI
- Kazemi-Darsanaki, 2013, J. Biol. Today’s World, 2
- Kenaan, 2016, Anal. Chem., 88, 3804, 10.1021/acs.analchem.5b04834 · DOI
- Kim, 2013, Biomicrofluidics, 7, 10.1063/1.4816934 · DOI
- Kuo, 1993, Biophys. J., 65, 2191, 10.1016/S0006-3495(93)81277-3 · DOI
- Lee, 2013, Kor. J. Chem. Eng., 30, 1934, 10.1007/s11814-013-0117-5 · DOI
- Li, 2016, Antibodies, 5, 19, 10.3390/antib5030019 · DOI
- Li, 2017, Lab Chip, 17, 2208, 10.1039/C7LC00277G · DOI
- Luchansky, 2010, Bioelectron, 26, 1283, 10.1016/j.bios.2010.07.010 · DOI
- Makaraviciute, 2013, Biosens. Bioelectron., 50, 460, 10.1016/j.bios.2013.06.060 · DOI
- Nagasaki, 2007, J. Colloid Interface Sci., 309, 524, 10.1016/j.jcis.2006.12.079 · DOI
- Pochechueva, 2014, J. Immunol. Methods, 412, 42, 10.1016/j.jim.2014.06.015 · DOI
- Soler, 2016, Biosens. Bioelectron., 79, 158, 10.1016/j.bios.2015.11.097 · DOI
- Stefansson, 2012, J. Nanotechnol, 2012, 1
- Strauch, 2014, Proc. Natl. Acad. Sci. Unit. States Am., 111, 675, 10.1073/pnas.1313605111 · DOI
- Sui, 2006, Anal. Chem., 78, 5543, 10.1021/ac060605z · DOI
- Tanislav, 2016, PloS One, 11, 10.1371/journal.pone.0157640 · DOI
- Thakur, 2013, J. Food Sci. Technol., 50, 625, 10.1007/s13197-012-0783-z · DOI
- Thévenot, 2001, Biosens. Bioelectron., 16, 121, 10.1016/S0956-5663(01)00115-4 · DOI
- Triggs, 2017, Optica, 4, 229, 10.1364/OPTICA.4.000229 · DOI
- Upasham, 2018, Adv. Health Care Technol., 4, 1, 10.2147/AHCT.S138543 · DOI
- Vashist, 2012, Diagnostics, 2, 23, 10.3390/diagnostics2030023 · DOI
- Wang, 1993, Appl. Optic., 32, 2606, 10.1364/AO.32.002606 · DOI
- Wawro, 2000, Proc. SPIE, 3911, 86, 10.1117/12.384889 · DOI
- Weimer, 2000, J. Biochem. Biophys. Methods, 45, 211, 10.1016/S0165-022X(00)00114-7 · DOI
- Wen, 2009, J. Immunol. Methods, 350, 97, 10.1016/j.jim.2009.07.011 · DOI
- Yakovleva, 2003, Bioelectron, 19, 21, 10.1016/S0956-5663(03)00126-X · DOI
- Yang, 2017, mAbs, 9, 1105, 10.1080/19420862.2017.1359455 · DOI
- Yuan, 2014, Adv. Biomater., 2014, 1, 10.1155/2014/261281 · DOI
Metadata
- Authors
- Kenaan, A., Li, K., Barth, I., Johnson, S., Song, J., & Krauss, T. F.
- Affiliations
- Shanghai Jiao Tong University (CN)
- University of York (GB)
- Corresponding author
- Krauss, Thomas F.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 153
- Pages
- 112047
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3002922055
- Cited by
- 61
- References
- 32
- Citations by year
- 2026: 7 · 2025: 14 · 2024: 9 · 2023: 15 · 2022: 4 · 2021: 7 · 2020: 5
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
- Keywords
- label-free biosensing, protein biomarkers, troponin, procalcitonin, C-reactive protein, antibody immobilization, PEG spacer, dielectric resonance, point-of-care testing, multiplexed detection, non-specific binding reduction
- MeSH terms
- Humans, Immunoassay, Polyethylene Glycols, Propylamines, Sensitivity and Specificity, Silanes, Surface Properties, Biomarkers, Silicon Compounds, Point-of-Care Systems, Surface Plasmon Resonance, Nanostructures, Antibodies, Immobilized, Limit of Detection, Quartz Crystal Microbalance Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›