Cited by 61Biosensors and Analytical DetectionAdvanced Biosensing Techniques and ApplicationsPhotonic and Optical Devices

The DOI matches its Crossref record; the references it cites are not checked yet.

Guided mode resonance sensor for the parallel detection of multiple protein biomarkers in human urine with high sensitivity

Open access

Abstract

The rising cost of global healthcare provision and new approaches to managing disease are driving the development of low-cost biosensing modalities, such as label-free photonic methods based on dielectric resonances. Here, we use the combined sensing and imaging capability of a guided mode resonance (GMR) sensor to detect multiple biomarkers (troponin, procalcitonin and C-Reactive Protein) in parallel in undiluted urine samples. A key requirement of such a biosensor is the simple and direct functionalization with suitable antibodies to ensure the disease-specific detection of protein biomarkers. Here, antibodies were immobilized using a succinimidyl-[(N-maleimidopropionamido)-hexaethyleneglycol] ester (SM(PEG)6) spacer. The polyethylene glycol (PEG) chemistry enables low detection limits of 10 pg mL-1 or better for all protein biomarkers, while minimizing non-specific binding compared to more commonly used strategies such as (3-Aminopropyl)triethoxysilane (APTES) or dextran. Our approach supports the vision of a simple yet highly sensitive diagnostic platform that could be used for pre-screening patients for a wide range of diseases at point-of-care, thereby relieving the pressure on overstretched healthcare services.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112047

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

References 32 · Cited by 61

Research works printed but not linked: 35

  1. Barnes, 1966, J. Immunol., 96, 854, 10.4049/jimmunol.96.5.854 · DOI
  2. Cunningham, 2010, J. Assoc. Lab. Autom., 15, 120, 10.1016/j.jala.2009.10.009 · DOI
  3. Dixit, 2011, Nat. Protoc., 6, 439, 10.1038/nprot.2011.304 · DOI
  4. Drayton, 2019, Semiconduct. Semimet., 100, 115, 10.1016/bs.semsem.2019.01.002 · DOI
  5. Eamudomkarn, 2018, PloS One, 13, 10.1371/journal.pone.0192598 · DOI
  6. Hughes-Jones, 1964, Immunology, 7, 72
  7. Jönsson, 2008, Lab Chip, 8, 1191, 10.1039/b800297e · DOI
  8. Kazemi-Darsanaki, 2013, J. Biol. Today’s World, 2
  9. Kenaan, 2016, Anal. Chem., 88, 3804, 10.1021/acs.analchem.5b04834 · DOI
  10. Kim, 2013, Biomicrofluidics, 7, 10.1063/1.4816934 · DOI
  11. Kuo, 1993, Biophys. J., 65, 2191, 10.1016/S0006-3495(93)81277-3 · DOI
  12. Lee, 2013, Kor. J. Chem. Eng., 30, 1934, 10.1007/s11814-013-0117-5 · DOI
  13. Li, 2016, Antibodies, 5, 19, 10.3390/antib5030019 · DOI
  14. Li, 2017, Lab Chip, 17, 2208, 10.1039/C7LC00277G · DOI
  15. Luchansky, 2010, Bioelectron, 26, 1283, 10.1016/j.bios.2010.07.010 · DOI
  16. Makaraviciute, 2013, Biosens. Bioelectron., 50, 460, 10.1016/j.bios.2013.06.060 · DOI
  17. Nagasaki, 2007, J. Colloid Interface Sci., 309, 524, 10.1016/j.jcis.2006.12.079 · DOI
  18. Pochechueva, 2014, J. Immunol. Methods, 412, 42, 10.1016/j.jim.2014.06.015 · DOI
  19. Soler, 2016, Biosens. Bioelectron., 79, 158, 10.1016/j.bios.2015.11.097 · DOI
  20. Stefansson, 2012, J. Nanotechnol, 2012, 1
  21. Strauch, 2014, Proc. Natl. Acad. Sci. Unit. States Am., 111, 675, 10.1073/pnas.1313605111 · DOI
  22. Sui, 2006, Anal. Chem., 78, 5543, 10.1021/ac060605z · DOI
  23. Tanislav, 2016, PloS One, 11, 10.1371/journal.pone.0157640 · DOI
  24. Thakur, 2013, J. Food Sci. Technol., 50, 625, 10.1007/s13197-012-0783-z · DOI
  25. Thévenot, 2001, Biosens. Bioelectron., 16, 121, 10.1016/S0956-5663(01)00115-4 · DOI
  26. Triggs, 2017, Optica, 4, 229, 10.1364/OPTICA.4.000229 · DOI
  27. Upasham, 2018, Adv. Health Care Technol., 4, 1, 10.2147/AHCT.S138543 · DOI
  28. Vashist, 2012, Diagnostics, 2, 23, 10.3390/diagnostics2030023 · DOI
  29. Wang, 1993, Appl. Optic., 32, 2606, 10.1364/AO.32.002606 · DOI
  30. Wawro, 2000, Proc. SPIE, 3911, 86, 10.1117/12.384889 · DOI
  31. Weimer, 2000, J. Biochem. Biophys. Methods, 45, 211, 10.1016/S0165-022X(00)00114-7 · DOI
  32. Wen, 2009, J. Immunol. Methods, 350, 97, 10.1016/j.jim.2009.07.011 · DOI
  33. Yakovleva, 2003, Bioelectron, 19, 21, 10.1016/S0956-5663(03)00126-X · DOI
  34. Yang, 2017, mAbs, 9, 1105, 10.1080/19420862.2017.1359455 · DOI
  35. Yuan, 2014, Adv. Biomater., 2014, 1, 10.1155/2014/261281 · DOI

Metadata

Authors
Kenaan, A., Li, K., Barth, I., Johnson, S., Song, J., & Krauss, T. F.
Affiliations
  • Shanghai Jiao Tong University (CN)
  • University of York (GB)
Corresponding author
Krauss, Thomas F.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2020-04
Volume
153
Pages
112047
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3002922055
Cited by
61
References
32
Citations by year
2026: 7 · 2025: 14 · 2024: 9 · 2023: 15 · 2022: 4 · 2021: 7 · 2020: 5
FWCI
2.44
Type
journal article
Language
en
Open access
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
Keywords
label-free biosensing, protein biomarkers, troponin, procalcitonin, C-reactive protein, antibody immobilization, PEG spacer, dielectric resonance, point-of-care testing, multiplexed detection, non-specific binding reduction
MeSH terms
Humans, Immunoassay, Polyethylene Glycols, Propylamines, Sensitivity and Specificity, Silanes, Surface Properties, Biomarkers, Silicon Compounds, Point-of-Care Systems, Surface Plasmon Resonance, Nanostructures, Antibodies, Immobilized, Limit of Detection, Quartz Crystal Microbalance Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review