The DOI matches its Crossref record; 216 of the 216 references it cites were found in a registry or an index.
Electrochemical biosensors for pathogen detection
Open accessAbstract
Recent advances in electrochemical biosensors for pathogen detection are reviewed. Electrochemical biosensors for pathogen detection are broadly reviewed in terms of transduction elements, biorecognition elements, electrochemical techniques, and biosensor performance. Transduction elements are discussed in terms of electrode material and form factor. Biorecognition elements for pathogen detection, including antibodies, aptamers, and imprinted polymers, are discussed in terms of availability, production, and immobilization approach. Emerging areas of electrochemical biosensor design are reviewed, including electrode modification and transducer integration. Measurement formats for pathogen detection are classified in terms of sample preparation and secondary binding steps. Applications of electrochemical biosensors for the detection of pathogens in food and water safety, medical diagnostics, environmental monitoring, and bio-threat applications are highlighted. Future directions and challenges of electrochemical biosensors for pathogen detection are discussed, including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, reusable biosensors for process monitoring applications, and low-cost, disposable biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–216 of 216
Bunyakul, N., & Baeumner, A. J. (2014) · Sensors · doi:10.3390/s150100547 · Cited by 67
3D nanogap interdigitated electrode array biosensors
Singh, K. V., Whited, A. M., Ragineni, Y., Barrett, T. W., King, J., & Solanki, R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3682-z · Cited by 66
Lam, B., Fang, Z., Sargent, E. H., & Kelley, S. O. (2011) · Analytical Chemistry · doi:10.1021/ac202599b · Cited by 65
Biosensors for waterborne viruses: Detection and removal
Altıntaş, Z., Gittens, M., Pocock, J., & Tothill, I. E. (2015) · Biochimie · doi:10.1016/j.biochi.2015.05.010 · Cited by 63
Biomolecular Steric Hindrance Effects Are Enhanced on Nanostructured Microelectrodes
Mahshid, S. S., Vallée‐Bélisle, A., & Kelley, S. O. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01595 · Cited by 52
Intrinsically conducting polymer nanowires for biosensing
Travaš‐Sejdić, J., Aydemir, N., Kannan, B., Williams, D. E., & Malmström, J. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00598h · Cited by 50
Das, R., Roychaudhuri, C., Maji, S., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.014 · Cited by 49
Yoo, M.-S., Shin, M., Kim, Y., Jang, M., Choi, Y.-E., Park, S. J., Choi, J. H., Lee, J., & Park, C. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.02.060 · Cited by 49
Multiplex diagnostic platforms for detection of biothreat agents
Cirino, N. M., Musser, K. A., & Egan, C. T. (2004) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.4.6.841 · Cited by 46
Yeh, P.-Y. J., Kizhakkedathu, J. N., Madden, J. D. W., & Chiao, M. (2007) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2007.04.007 · Cited by 42
Cesewski, E., Haring, A. P., Tong, Y., Singh, M., Thakur, R., Laheri, S., Read, K. A., Powell, M. D., Oestreich, K. J., & Johnson, B. N. (2018) · Lab on a Chip · doi:10.1039/c8lc00427g · Cited by 40
Self-citationYan, L., Xiong, Y., Fang, L., et al. (2017) · Theranostics · doi:10.7150/thno.17544 · Cited by 38
Minimum infective dose of HIV for parenteral dosimetry
Reid, S. R., & Juma, O. A. (2009) · International Journal of STD & AIDS · doi:10.1258/ijsa.2009.009284 · Cited by 17
Németh, E., Adányi, N., Halász, A., Váradi, M., & Szendrő, I. (2007) · Biomolecular Engineering · doi:10.1016/j.bioeng.2007.10.001 · Cited by 12
Measuring and Mitigating PCR Bias in Microbiome DataPreprint
Silverman, J. D., Bloom, R. J., Jiang, S., Durand, H. K., Mukherjee, S., & David, L. A. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/604025 · Cited by 10
Biosensors for Sustainable Food - New Opportunities and Technical Challenges
(2016) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(16)30128-3 · Cited by 8
Cited by
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Biosensors applications in medical field: A brief review
Haleem, A., Javaid, M., Singh, R. P., Suman, R., & Rab, S. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100100 · Cited by 600
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Habibi-Yangjeh, A., Asadzadeh-Khaneghah, S., Feizpoor, S., & Rouhi, A. (2020) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2020.07.047 · Cited by 473
Metadata
- Authors
- Cesewski, E., & Johnson, B. N.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 159
- Pages
- 112214
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3015544413
- Cited by
- 902
- References
- 216
- FWCI
- 43.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.