The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recent progress in immunosensors for pesticides
Abstract
Immunosensors for rapid detection of pesticide residues has attracted considerable interest in the past few years for healthcare and environmental monitoring. And the publications have grown exponentially over the past decades, making it a trending hot-spot. Therefore, this review first examines the current situation regarding pesticide residue in various foods, feeds, traditional Chinese medicines and environmental samples. Then, the primary focus is on the recent development of the proposed immunosensors for pesticide detection in the past five years, with particular emphasis on the fluorescence, colorimetric, chemiluminescence, electrochemiluminescence, surface plasmon resonance, surface-enhanced Raman spectroscopy, electrochemical and piezoelectric sensors. Beyond a highlight of the real-world application and advantages of these emerging immunosensors for pesticide inspection, this paper also discusses their potential limits and current challenges, as well as future perspectives. This review will provide powerful insights to researchers for the future development of immunosensors, as well as their broader application in different fields, such as analytical chemistry, food safety control, clinical diagnostics, and environmental monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Li, X., Wang, M., Zhao, J., Guo, H., Gao, X., Xiong, Z., & Zhao, L. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.01.018 · Cited by 52
Cited by
Rathi, B. S., Kumar, P. S., & Vo, D.-V. N. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.149134 · Cited by 707
Ahmad, M. F., Ahmad, F. A., Alsayegh, A. A., Zeyaullah, M., AlShahrani, A. M., Muzammil, K., Saati, A. A., Wahab, S., Elbendary, E. Y., Kambal, N., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e29128 · Cited by 624
RetractedUmapathi, R., Sonwal, S., Lee, M. J., Mohana Rani, G., Lee, E.-S., Jeon, T.-J., Kang, S.-M., Oh, M.-H., & Huh, Y. S. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214061 · Cited by 349
Advances in optical-sensing strategies for the on-site detection of pesticides in agricultural foods
Umapathi, R., Park, B., Sonwal, S., Rani, G. M., Cho, Y., & Huh, Y. S. (2022) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.11.018 · Cited by 307
Metadata
- Authors
- Fang, L., Liao, X., Jia, B., Shi, L., Kang, L., Zhou, L., & Kong, W.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 164
- Pages
- 112255
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3023210680
- Cited by
- 197
- References
- 1
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.