CoChat

Graphene biosensors for bacterial and viral pathogens

Open access
Jiang, Zixin, Feng, Bo, Xu, Jin, Qing, Taiping, Zhang, Peng, Qing, Zhihe · 2020 · Biosensors and Bioelectronics
Cited by 188

The DOI matches its Crossref record; 137 of the 137 references it cites were found in a registry or an index.

Abstract

The infection and spread of pathogens (e.g., COVID-19) pose an enormous threat to the safety of human beings and animals all over the world. The rapid and accurate monitoring and determination of pathogens are of great significance to clinical diagnosis, food safety and environmental evaluation. In recent years, with the evolution of nanotechnology, nano-sized graphene and graphene derivatives have been frequently introduced into the construction of biosensors due to their unique physicochemical properties and biocompatibility. The combination of biomolecules with specific recognition capabilities and graphene materials provides a promising strategy to construct more stable and sensitive biosensors for the detection of pathogens. This review tracks the development of graphene biosensors for the detection of bacterial and viral pathogens, mainly including the preparation of graphene biosensors and their working mechanism. The challenges involved in this field have been discussed, and the perspective for further development has been put forward, aiming to promote the development of pathogens sensing and the contribution to epidemic prevention.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2020.112471

Cites

137 of 137 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Graphene-Based Ultracapacitors

    Stoller, M. D., Park, S., Zhu, Y., An, J., & Ruoff, R. S. (2008) · Nano Letters · doi:10.1021/nl802558y · Cited by 8,373 · cited 1×

    “In addition, graphene has a lamellar structure with large theoretical specific surface area of 2630 m2/g (Stoller et al., 2008).”
    Background
  • Ultrahigh electron mobility in suspended graphene

    Bolotin, K. I., Sikes, K. J., Jiang, Z., Klima, M., Fudenberg, G., Hone, J., Kim, P., & Stormer, H. L. (2008) · Solid State Communications · doi:10.1016/j.ssc.2008.02.024 · Cited by 8,057 · cited 1×

    “It was found that the electron mobility in graphene could be as high as 10,000–50,000 cm2 V− 1 s− 1 at room temperature, and the intrinsic mobility limit also exceeds 200,000 cm2 V− 1 s− 1 (Bolotin et al., 2008; Sreeprasad and Berry, 2013).”
    BackgroundSelf-citation
  • Honeycomb Carbon: A Review of Graphene

    Allen, M. J., Tung, V. C., & Kaner, R. B. (2010) · Chemical Reviews · doi:10.1021/cr900070d · Cited by 6,998 · cited 1×

    “Graphene, a one-atom-thick two-dimensional carbon nanomaterial with hexagonal honeycomb lattice, was isolated from graphite for the first time in 2004 (Allen et al., 2010).”
    Background
  • Large Area, Few-Layer Graphene Films on Arbitrary Substrates by Chemical Vapor Deposition

    Reina, A., Jia, X., Ho, J., Nezich, D., Son, H., Bulovic, V., Dresselhaus, M. S., & Kong, J. (2009) · Nano Letters · doi:10.1021/nl801827v · Cited by 5,881 · cited 1×

    “Although CVD is currently expensive and imperfect, it is believed to be the most promising method for industrialized production of graphene (Reina et al., 2009).”
    Background
  • Antimicrobial peptides: pore formers or metabolic inhibitors in bacteria?

    Brogden, K. A. (2005) · Nature Reviews Microbiology · doi:10.1038/nrmicro1098 · Cited by 5,829 · cited 2×

    “AMPs, a class of cationic and amphiphilic short-peptide, could bind to the surface of microbial cells via electrostatic interactions with LPS or other negatively-charged molecules on bacterial membranes, and present their antibacterial ability through membrane destruction (Brogden, 2005).”
    Background
  • Molecular Beacons: Probes that Fluoresce upon Hybridization

    Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155 · cited 1×

    “Nucleic acid probes have been developed for biosensor technology due to their superior recognition specificity, facile synthesis in vitro, excellent chemical stability, modifiable ability and good affinity for diverse platforms (Qing et al., 2020b; Qing et al., 2019b; Tyagi and Kramer, 1996).”
    Background
  • PNA hybridizes to complementary oligonucleotides obeying the Watson–Crick hydrogen-bonding rules

    Egholm, M., Buchardt, O., Christensen, L., Behrens, C., Freier, S. M., Driver, D. A., Berg, R. H., Kim, S. K., Norden, B., & Nielsen, P. E. (1993) · Nature · doi:10.1038/365566a0 · Cited by 2,079 · cited 1×

    “And on the other hand, despite a significant structural change compared to natural DNA or other DNA analogs, PNAs are still capable of recognizing and binding specific DNA or RNA sequences following the Watson-Crick hydrogen bonding principle (Egholm et al., 1993).”
    Background
  • Graphene-Based Antibacterial Paper

    Hu, W., Peng, C., Luo, W., Lv, M., Li, X., Li, D., Huang, Q., & Fan, C. (2010) · ACS Nano · doi:10.1021/nn101097v · Cited by 2,003 · cited 1×

    “In 2010, Fan and Huang et al. first found that GO and rGO effectively inhibited the growth of E. coli, and confirmed the cell membrane damage of killed E. coil via scanning electron microscopy (SEM) (Hu et al., 2010).”
  • Biological and chemical sensors based on graphene materials

    Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748 · cited 2×

    “For instance, non-covalent crosslinking has no impact on the instinct properties and structure of nanomaterials as well as the activity of biomolecules (Liu et al., 2012b).”
    Background
  • The expanding scope of antimicrobial peptide structures and their modes of action

    Nguyen, L. T., Haney, E. F., & Vogel, H. J. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.05.001 · Cited by 1,604 · cited 1×

    “As part of the innate immune system of many organisms, antimicrobial peptides (AMPs) play an essential role in protecting against microbial invasion, including viruses, bacteria, and fungi (Nguyen et al., 2011).”
    Background

Show all 137 references

Metadata

Authors
Jiang, Z., Feng, B., Xu, J., Qing, T., Zhang, P., & Qing, Z.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2020-10
Volume
166
Pages
112471
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3044462443
Cited by
188
References
137
FWCI
9.96
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Graphene biosensors for bacterial and viral pathogens. https://app.cochat.ai/papers/10.1016/j.bios.2020.112471
The paper
Jiang, Z., Feng, B., Xu, J., Qing, T., Zhang, P., & Qing, Z. (2020). Graphene biosensors for bacterial and viral pathogens. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112471

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.