A terahertz metamaterial biosensor for sensitive detection of microRNAs based on gold-nanoparticles and strand displacement amplification
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Terahertz (THz) spectroscopy has drawn great interest for the functional and conformational investigations of nucleic acids, but its intrinsic sensitivity hinders potential bio-sensing applications. Here, a novel THz biosensor was developed for detecting microRNA (miRNA) samples based on metamaterials coupled with nanoparticles and strand displacement amplification (SDA). In this method, the SDA reaction amplifies the target miRNA and generates copious yields of secondary DNA molecules (Trigger DNA), which are subsequently conjugated to metallic nanoparticles that form nanoparticle-Trigger DNA complexes. These complexes produce remarkable frequency shifts of metamaterials when linked to a large refractive index metallic nanoparticle like Au. The dependence of the metamaterial resonance on the nanoparticle diameter and metal type was investigated experimentally and theoretically. Under optimal conditions, the THz metamaterial biosensor presents good detection sensitivity with a limit of detection of 14.54 aM and exhibits a linear response for miRNA-21 at a concentration range from 1 fM to 10 pM. By measuring the miRNA-21 in spiked clinical serum samples, the sample recoveries were determined to be in the range between 90.92% and 107.01%. These findings demonstrate that the novel THz biosensor offers the capability for highly sensitive miRNA detection, with noteworthy potential applications in nucleic acid analysis and cancer diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Cited by
Lyu, J., Huang, L., Chen, L., Zhu, Y., & Zhuang, S. (2024) · Photonics Research · doi:10.1364/prj.508136 · Cited by 233
Recent advances of nucleic acid-based cancer biomarkers and biosensors
Zhao, J., Xia, K., He, P., Wei, G., Zhou, X., & Zhang, X. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215456 · Cited by 44
Metadata
- Authors
- Yang, K., Li, J., Lamy de la Chapelle, M., Huang, G., Wang, Y., Zhang, J., Xu, D., Yao, J., Yang, X., & Fu, W.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 175
- Pages
- 112874
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3106898698
- Cited by
- 180
- References
- 1
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A terahertz metamaterial biosensor for sensitive detection of microRNAs based on gold-nanoparticles and strand displacement amplification. https://app.cochat.ai/papers/10.1016/j.bios.2020.112874
- The paper
- Yang, K., Li, J., Lamy de la Chapelle, M., Huang, G., Wang, Y., Zhang, J., Xu, D., Yao, J., Yang, X., & Fu, W. (2021). A terahertz metamaterial biosensor for sensitive detection of microRNAs based on gold-nanoparticles and strand displacement amplification. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112874
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.