The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Exploring the fundamental limit of antimicrobial susceptibility by near-single-cell electrical impedance spectroscopy
Open accessAbstract
Many novel susceptibility tests are being developed to tackle the worldwide problem of antimicrobial resistance (AMR). The key driver behind these developments, that is the need to reduce the response time, requires an understanding of which bacterial characteristic needs to be monitored to provide a rapid and ideally universal signature of susceptibility. Many characteristics have already been studied, most notably bacterial growth, metabolism and motility. Here, we consider electrical impedance to directly access bacterial metabolism, which can be considered a fundamental indicator of bacterial viability. By studying the electrical response of individual bacteria to an antibiotic challenge, we detect antimicrobial action close to its biological limit. Specifically, we find that it takes 30-60 min to register significant changes in impedance for clinical concentrations of antibiotics, in line with other rapid indicators. Our findings suggest that 60 min is the fundamental lower limit of response time for a realistic susceptibility test at clinically relevant antibiotic concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The impedance-based assay is a powerful technique that can detect alterations in the electrical properties of microbial cells in response to interactions with antimicrobial agents [95].”
From Methods for screening and evaluation of antimicrobial activity: A review of protocols, advantages, and limitations (2024) · cites this paper as [95]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Challenges in measuring and understanding biological noise
Eling, N., Morgan, M. D., & Marioni, J. C. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0130-6 · Cited by 247
A fast impedance-based antimicrobial susceptibility test
Spencer, D. C., Paton, T. F., Mulroney, K. T., Inglis, T. J. J., Sutton, J. M., & Morgan, H. (2020) · Nature Communications · doi:10.1038/s41467-020-18902-x · Cited by 183
Research works printed but not linked: 36
- Anand, 2021, Anal. Chim. Acta, 1166, 10.1016/j.aca.2021.338547 · DOI
- Avesar, 2017, Proc. Natl. Acad. Sci. U. S. A, 114, E5787, 10.1073/pnas.1703736114 · DOI
- Baltekin, 2017, Proc. Natl. Acad. Sci. USA, 114, 9170, 10.1073/pnas.1708558114 · DOI
- Belenky, 2015, Cell Rep., 13, 968, 10.1016/j.celrep.2015.09.059 · DOI
- van Belkum, 2020, Nat. Rev. Microbiol., 18, 299, 10.1038/s41579-020-0327-x · DOI
- Brosel-Oliu, 2019, Anal. Chim. Acta, 1088, 1, 10.1016/j.aca.2019.09.026 · DOI
- Butler, 2019, Biosens. Bioelectron., 129, 269, 10.1016/j.bios.2018.09.057 · DOI
- Butler, 2019, Biosens. Bioelectron., 129, 269, 10.1016/j.bios.2018.09.057 · DOI
- Carroll, 2006, J. Clin. Microbiol., 44, 3506, 10.1128/JCM.00994-06 · DOI
- Chen, 2018, Biosens. Bioelectron., 99, 416, 10.1016/j.bios.2017.08.017 · DOI
- Choi, 2014, Sci. Transl. Med., 6, 10.1126/scitranslmed.3009650 · DOI
- Giesen, 2010, BMC Fam. Pract., 11, 10.1186/1471-2296-11-78 · DOI
- Gomez, 2002, Sensor. Actuator. B Chem., 86, 198, 10.1016/S0925-4005(02)00175-2 · DOI
- Harrington, 2011, Electrochim. Acta, 56, 8005, 10.1016/j.electacta.2011.01.067 · DOI
- Hudzicki, 2012, Am. Soc. Microbiol., 1
- Jorgensen, 2009, Clin. Infect. Dis., 49, 1749, 10.1086/647952 · DOI · Paper page
- Jusková, 2021, ACS Sens., 6, 2202, 10.1021/acssensors.1c00020 · DOI
- Kara, 2018, Lab Chip, 18, 743, 10.1039/C7LC01019B · DOI
- Kohanski, 2010, Nat. Rev. Microbiol., 8, 423, 10.1038/nrmicro2333 · DOI
- Li, 2014, Anal. Chem., 86, 3131, 10.1021/ac5001306 · DOI
- Lidstrom, 2010, Nat. Chem. Biol., 6, 705, 10.1038/nchembio.436 · DOI
- Liu, 2020, Lab Chip, 20, 3144, 10.1039/D0LC00579G · DOI
- Lupetti, 2010, Clin. Microbiol. Infect., 16, 986, 10.1111/j.1469-0691.2009.03006.x · DOI
- Pitruzzello, 2022, Small Sci., 2, 10.1002/smsc.202270010 · DOI
- Pitruzzello, 2020, Nanophotonics for bacterial detection and antimicrobial susceptibility testing, Nanophotonics, 9, 4447, 10.1515/nanoph-2020-0388 · DOI
- Pitruzzello, 2019, Lab Chip, 19, 1417, 10.1039/C8LC01397G · DOI
- Poirel, 2017, Clin. Microbiol. Rev., 30, 557, 10.1128/CMR.00064-16 · DOI
- Rolinson, 1977, J. Antimicrob. Chemother., 3, 541, 10.1093/jac/3.6.541 · DOI
- Stewart, 2004, J. Exp. Med., 4, 235, 10.1084/jem.4.2.235 · DOI
- Stokes, 2019, Cell Metabol., 30, 251, 10.1016/j.cmet.2019.06.009 · DOI
- Swami, 2021, Biosens. Bioelectron., 182, 10.1016/j.bios.2021.113190 · DOI
- Swami, 2022, Biosens. Bioelectron., 200, 10.1016/j.bios.2021.113876 · DOI
- Vasala, 2020, Front. Cell. Infect. Microbiol., 10, 10.3389/fcimb.2020.00308 · DOI
- Wang, 2010, Curr. Biol., 20, 1099, 10.1016/j.cub.2010.04.045 · DOI · Paper page
- Yang, 2020, All-electrical monitoring of bacterial antibiotic susceptibility in a microfluidic device, Proc. Nat. Acad. Sci., 117, 10639, 10.1073/pnas.1922172117 · DOI
- Zhang, 2022, Small Methods, 6
Cited by
Sorted by citations
Hossain, T. J. (2024) · European Journal of Microbiology and Immunology · doi:10.1556/1886.2024.00035 · Cited by 392
Metadata
- Authors
- Pitruzzello, G., Johnson, S., & Krauss, T. F.
- Affiliations
- University of York (GB)
- Corresponding author
- Pitruzzello, Giampaolo
- Krauss, Thomas F.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2023-03
- Volume
- 224
- Pages
- 115056
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4313368492
- Cited by
- 20
- References
- 2
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 10 · 2023: 3
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/P02324X/1, EP/P030017/1)
- Royal Society
- Topics
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- antimicrobial susceptibility testing, electrical impedance spectroscopy, single-cell analysis, bacterial metabolism, bacterial viability, antimicrobial resistance
- MeSH terms
- Anti-Bacterial Agents, Bacteria, Microbial Sensitivity Tests, Biosensing Techniques, Dielectric Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review