CoChat

Clinical impact of peripherally inserted central catheters vs implanted port catheters in patients with cancer: an open-label, randomised, two-centre trial

Open access
Taxbro, Knut, Hammarskjöld, Fredrik, Thelin, Bo, Lewin, Freddi, Hagman, Helga, Hanberger, Håkan, Berg, Sören · 2019 · British Journal of Anaesthesia
Cited by 191

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND Centrally inserted totally implanted vascular access ports (PORTs) and peripherally inserted central catheters (PICCs) are widely used for the administration of chemotherapy. Our aim was to study the incidence of catheter-related deep venous thrombosis in patients with cancer receiving chemotherapy through either a PICC or a PORT. METHODS Adults with non-haematological cancer (mainly breast and colorectal) from two Swedish oncology centres were included and followed for up to 1 yr. Patients were randomly assigned to receive a single-lumen PICC or PORT. The primary end point was the occurrence of a clinically significant catheter-related deep venous thrombosis, and the secondary end point was a composite of adverse events related to the catheter: insertion complication, thrombosis, occlusion, infection, and mechanical problems. RESULTS The trial recruited 399 participants (PICC, n=201; PORT, n=198) between March 2013 and February 2017. The PICCs were associated with 16 (8%) deep venous thromboses compared with two (1%) in the PORT group (HR=10.2; 95% confidence interval, 2.3-44.6; P=0.002). The overall incidence of composite adverse events was higher for patients with a PICC compared with those with a PORT (HR=2.7; 95% confidence interval, 1.6-4.6; P<0.001). CONCLUSIONS PICCs are associated with higher risk for catheter-related deep venous thrombosis and other adverse events when compared with PORTs. This increased risk should be considered when choosing a vascular access device for chemotherapy, especially in patients with solid malignancy. CLINICAL TRIAL REGISTRATION NCT01971021.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bja.2019.01.038

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 191

Metadata

Authors
Taxbro, K., Hammarskjöld, F., Thelin, B., Lewin, F., Hagman, H., Hanberger, H., & Berg, S.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2019-06
Volume
122
Issue
6
Pages
734-741
ISSN
0007-0912 (ISSN-L)
OpenAlex
W2939650487
Cited by
191
References
2
FWCI
25.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical impact of peripherally inserted central catheters vs implanted port catheters in patients with cancer: an open-label, randomised, two-centre trial. https://app.cochat.ai/papers/10.1016/j.bja.2019.01.038
The paper
Taxbro, K., Hammarskjöld, F., Thelin, B., Lewin, F., Hagman, H., Hanberger, H., & Berg, S. (2019). Clinical impact of peripherally inserted central catheters vs implanted port catheters in patients with cancer: an open-label, randomised, two-centre trial. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2019.01.038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.