CoChat

Measurement of quality of recovery after surgery using the 15-item quality of recovery scale: a systematic review and meta-analysis

Open access
Myles, Paul S., Shulman, Mark A., Reilly, Jennifer, Kasza, Jessica, Romero, Lorena · 2022 · British Journal of Anaesthesia
Cited by 236

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

BACKGROUND There are very few patient-centred global outcome measures of recovery in the days or weeks after surgery. This meta-analysis evaluated the psychometric properties and clinical acceptability of the 15-item quality of recovery (QoR-15) scale. METHODS We searched bibliographic databases for studies undertaking psychometric evaluation of the QoR-15 or using the QoR-15 as an outcome measure after surgery. Record screening, data extraction, and quality assessments were independently done by two researchers. Weighted averages estimating overall summary statistics across all the studies were calculated using random-effects meta-analysis. Pooled correlation coefficients were transformed using a Fisher z-transformation and then back-transformed to calculate pooled results. The four co-primary endpoints were validity, reliability, responsiveness, and clinical utility of the QoR-15 scale. RESULTS A total of 26 unique studies met the eligibility criteria, yielding up to 22 847 patients across 16 countries, in 15 languages. A further 172 studies in a further 18 countries and six languages used the QoR-15 as an outcome measure. The QoR-15 had excellent discriminant validity, with the mean difference in QoR-15 scores in patients with and without postoperative complications (9.6; 95% confidence interval [CI], 5.9-13.3; P<0.001), and good convergent validity (for a global visual analogue recovery scale, pooled r=0.63; 95% CI, 0.54-0.71). There was excellent reliability: internal consistency (pooled α=0.85; 95% CI, 0.83-0.87), split-half reliability=0.80 (95% CI, 0.75-0.84), and test-retest reliability=0.97 (95% CI, 0.95-0.98). There was also high responsiveness (pooled standardised response mean=0.87; 95% CI, 0.65-1.08), patient recruitment into evaluation studies (96%; 95% CI, 93-99), and excellent completion and return rates (91%; 95% CI, 84-96). The mean time to complete the QoR-15 was 2.7 (95% CI, 2.2-3.1) min. CONCLUSIONS The QoR-15 is a valid, reliable, and responsive patient-centred outcome metric in surgical patients. It is highly acceptable to both patients and clinicians. REGISTRATION Open Science Framework Identifier: DOI 10.17605/OSF.IO/78HTA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bja.2022.03.009

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Metadata

Authors
Myles, P. S., Shulman, M. A., Reilly, J., Kasza, J., & Romero, L.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2022-06
Volume
128
Issue
6
Pages
1029-1039
ISSN
0007-0912 (ISSN-L)
OpenAlex
W4224115577
Cited by
236
References
10
FWCI
12.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of quality of recovery after surgery using the 15-item quality of recovery scale: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.bja.2022.03.009
The paper
Myles, P. S., Shulman, M. A., Reilly, J., Kasza, J., & Romero, L. (2022). Measurement of quality of recovery after surgery using the 15-item quality of recovery scale: a systematic review and meta-analysis. British Journal of Anaesthesia. https://doi.org/10.1016/j.bja.2022.03.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.