Cited by 438Advanced Fluorescence Microscopy TechniquesDiffusion Coefficients in LiquidsOptical Imaging and Spectroscopy Techniques

Fluorescence Correlation Spectroscopy: Past, Present, Future

Open access
Elson, Elliot L.·2011·Biophysical Journal

Abstract

In recent years fluorescence correlation spectroscopy (FCS) has become a routine method for determining diffusion coefficients, chemical rate constants, molecular concentrations, fluorescence brightness, triplet state lifetimes, and other molecular parameters. FCS measures the spatial and temporal correlation of individual molecules with themselves and so provides a bridge between classical ensemble and contemporary single-molecule measurements. It also provides information on concentration and molecular number fluctuations for nonlinear reaction systems that complement single-molecule measurements. Typically implemented on a fluorescence microscope, FCS samples femtoliter volumes and so is especially useful for characterizing small dynamic systems such as biological cells. In addition to its practical utility, however, FCS provides a window on mesoscopic systems in which fluctuations from steady states not only provide the basis for the measurement but also can have important consequences for the behavior and evolution of the system. For example, a new and potentially interesting field for FCS studies could be the study of nonequilibrium steady states, especially in living cells.

Integrity signals

Registry

Crossref · 10.1016/j.bpj.2011.11.012

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Fluorescence offers advantages in the monitoring of biological variables, such as high sensitivity, simplicity and speed, low background, selectivity, and applicability to living organisms in a non-invasive and non-destructive way.

    “Fluorescence offers a number of advantages in the monitoring of biological variables, such as its high sensitivity to monitor sub-nanomolar concentrations or even at the level of a single molecule, simplicity and speed, low background due to the differences between excitation and emission wavelengths, selectivity due to the ability to recognize specific fluorophores within a mixture with nonfluore”

    From Software sensors in the monitoring of microalgae cultivations (2024) · cites this paper as Elson 2011

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Elson, E. L.
Affiliations
Washington University in St. Louis (US)
Corresponding author
Elson, Elliot L.
Venue
Biophysical Journal
Publisher
Elsevier BV
Published
2011-12
Volume
101
Issue
12
Pages
2855-2870
ISSN
0006-3495 (ISSN-L)
OpenAlex
W2032003671
Cited by
438
References
2
Citations by year
2026: 21 · 2025: 32 · 2024: 36 · 2023: 31 · 2022: 24 · 2021: 39 · 2020: 49 · 2019: 28 · 2018: 35 · 2017: 30 · 2016: 21 · 2015: 28 · 2014: 19 · 2013: 23 · 2012: 21
FWCI
2.43
Type
journal article
Language
en
Open access
Locations
  • Biophysical Journal (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (R01GM084200)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Chemistry › Spectroscopy › Diffusion Coefficients in Liquids
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
fluorescence correlation spectroscopy, diffusion coefficient, chemical rate constants, molecular concentration, fluorescence intensity, triplet lifetime, single-molecule measurement, concentration fluctuations, mesoscopic systems, nonequilibrium steady states, living cells
MeSH terms
Forecasting, Spectrometry, Fluorescence, Molecular Probe Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review