The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Probing Red Blood Cell Morphology Using High-Frequency Photoacoustics
Open accessAbstract
A method that can rapidly quantify variations in the morphology of single red blood cells (RBCs) using light and sound is presented. When irradiated with a laser pulse, an RBC absorbs the optical energy and emits an ultrasonic pressure wave called a photoacoustic wave. The power spectrum of the resulting photoacoustic wave contains distinctive features that can be used to identify the RBC size and morphology. When particles 5-10 μm in diameter (such as RBCs) are probed with high-frequency photoacoustics, unique periodically varying minima and maxima occur throughout the photoacoustic signal power spectrum at frequencies >100 MHz. The location and distance between spectral minima scale with the size and morphology of the RBC; these shifts can be used to quantify small changes in the morphology of RBCs. Morphological deviations from the normal biconcave RBC shape are commonly associated with disease or infection. Using a single wide-bandwidth transducer sensitive to frequencies between 100 and 500 MHz, we were able to differentiate healthy RBCs from irregularly shaped RBCs (such as echinocytes, spherocytes, and swollen RBCs) with high confidence using a sample size of just 21 RBCs. As each measurement takes only seconds, these methods could eventually be translated to an automated device for rapid characterization of RBC morphology and deployed in a clinical setting to help diagnose RBC pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Cited by
Photothermal therapy and photoacoustic imaging via nanotheranostics in fighting cancer
Liu, Y., Bhattarai, P., Dai, Z., & Chen, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00618k · Cited by 2,904
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Oelze, M. L., & Mamou, J. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2513958 · Cited by 383
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Strohm, E. M., Berndl, E. S. L., & Kolios, M. C.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 105
- Issue
- 1
- Pages
- 59-67
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2154679409
- Cited by
- 159
- References
- 1
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Probing Red Blood Cell Morphology Using High-Frequency Photoacoustics. https://app.cochat.ai/papers/10.1016/j.bpj.2013.05.037
- The paper
- Strohm, E. M., Berndl, E. S. L., & Kolios, M. C. (2013). Probing Red Blood Cell Morphology Using High-Frequency Photoacoustics. Biophysical Journal. https://doi.org/10.1016/j.bpj.2013.05.037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.