Out of thin air: hyperventilation-triggered seizures
Open accessAbstract
Voluntary hyperventilation triggers seizures in the vast majority of people with absence epilepsy. The mechanisms that underlie this phenomenon remain unknown. Herein, we review observations - many made long ago - that provide insight into the relationship between breathing and absence seizures.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Another EEG with activation by hyperventilation 3 weeks later revealed normal results without any sign of epilepsy.
“Another electroencephalography with activation by hyperventilation 3 weeks later also revealed normal results without any sign of epilepsy (in particular absence and temporal lobe epilepsy) (91–93).”
From Combined Fainting and Psychogenic Non-epileptic Seizures as Significant Therapy Hurdles in Blood-Injury-Injection Phobia: A Mini-Review and Case Report (2022) · cites this paper as [91]
The “Hyperventilation triggers absence seizures” section says hyperventilation during EEG is commonly used to diagnose absence epilepsy. It does not report a repeat EEG three weeks later, a normal result in the person described, or an assessment of temporal lobe epilepsy. No page number is available in our copy. (LLM, conf=0.78)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 123 · Cited by 30
Research works printed but not linked: 2
- Boron W, Boulpaep EL, 2009 Medical Physiology. Saunders.
- Jones EG, 2007 The Thalamus, Vol. 1 Cambridge University Press.
- Authors
- Salvati, K. A., & Beenhakker, M. P.
- Affiliations
- University of Virginia (US)
- Corresponding author
- Beenhakker, Mark P.
- Venue
- Brain Research
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 1703
- Pages
- 41-52
- ISSN
- 0006-8993 (ISSN-L)
- PMC
- PMC6546426
- OpenAlex
- W2781147883
- Cited by
- 30
- References
- 123
- Citations by year
- 2026: 3 · 2024: 6 · 2023: 8 · 2022: 3 · 2021: 3 · 2020: 5 · 2019: 2
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Brain Research (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of General Medical Sciences (T32GM007055)
- National Institute of Neurological Disorders and Stroke (R01NS099586)
- Topics
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- hyperventilation, absence epilepsy, absence seizures, seizure triggers
- MeSH terms
- Brain, Cerebral Cortex, Epilepsy, Absence, Humans, Hyperventilation, Respiration, Seizures, Thalamus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review