Experimental Characterization of the Electric Field Distribution Induced by TMS Devices
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND In transcranial magnetic stimulation (TMS) a strong, brief current pulse driven through a coil is used for non-invasively stimulating the cortex. Properties of the electric field (E-field) induced by the pulse together with physiological parameters determine the outcome of the stimulation. In research and clinical use, TMS is delivered using a wide range of different coils and stimulator units, all having their own characteristics; however, the parameters of the induced E-field are often inadequately known by the user. OBJECTIVE To better understand how the use of a specific TMS device may affect the resulting cortical stimulation, our objective was to develop an instrument for automated measurement of the E-fields induced by TMS coils in spherically symmetric conductors approximating the head. METHODS We built a saline-free, robotized measurement tool based on the triangle construction. The 5-mm-wide measurement probe allows complete sampling of the induced E-field at the studied depth. We used the instrument to characterize TMS coils and stimulators made by two companies. RESULTS The measurements revealed that all tested stimulators performed as expected, but we also found significant differences between the different stimulators. Measurements of different coil specimens of the same stimulator models agreed with each other. CONCLUSION The presented TMS calibrator allows a straightforward characterization of the E-fields induced by TMS coils. By performing measurements using this kind of a tool helps in ensuring that an investigator knows the properties of the E-field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breakdown of cortical effective connectivity during sleep
Massimini, M., Ferrarelli, F., Huber, R., Esser, S. K., Singh, H., & Tononi, G. (2005) · Science · doi:10.1126/science.1117256 · Cited by 1,534
Cited by
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
“of the field may be reduced compared to conventional coils due to thicker casing (Koponen et al., 2018; Nieminen et al., 2015).”
Self-citationConsciousness and cortical responsiveness: a within-state study during non-rapid eye movement sleep
Nieminen, J. O., Gosseries, O., Massimini, M., Saad, E., Sheldon, A. D., Boly, M., Siclari, F., Postle, B. R., & Tononi, G. (2016) · Scientific Reports · doi:10.1038/srep30932 · Cited by 61
Self-citationCattani, A., Galluzzi, A., Fecchio, M., Pigorini, A., Mattia, M., & Massimini, M. (2023) · eneuro · doi:10.1523/eneuro.0435-22.2023 · Cited by 21
Metadata
- Authors
- Nieminen, J. O., Koponen, L. M., & Ilmoniemi, R. J.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 8
- Issue
- 3
- Pages
- 582-589
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2110477558
- Cited by
- 109
- References
- 1
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.