A visual and narrative timeline of US FDA milestones for Transcranial Magnetic Stimulation (TMS) devices
Open accessThe DOI matches its Crossref record.
Abstract
It has been over a decade since the initial US Food and Drug Administration (FDA) approval of Transcranial Magnetic Stimulation (TMS). The technology was first approved for treating Major Depressive Disorder (MDD) in adults who have not responded satisfactorily to prior antidepressant medications in 2008 using the Neuronetics Neurostar System (DEN070003). Since then, refinement and optimization of TMS has paved the way to new and emerging technology that improves and broadens the clinical utility of TMS – such as pulse train protocols (e.g., iTBS and 18/20 Hz stimulation), neuronavigational systems, and electromagnetic coil technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accelerated Theta Burst Stimulation: Safety, Efficacy, and Future Advancements
Cole, E., O’Sullivan, S. J., Tik, M., & Williams, N. R. (2024) · Biological Psychiatry · doi:10.1016/j.biopsych.2023.12.004 · Cited by 79
Metadata
- Authors
- Cohen, S. L., Bikson, M., Badran, B. W., & George, M. S.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2022-01
- Volume
- 15
- Issue
- 1
- Pages
- 73-75
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W3214323141
- Cited by
- 217
- References
- 0
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.