Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Improved multiscale permutation entropy for biomedical signal analysis: Interpretation and application to electroencephalogram recordings

Open access
Azami, Hamed, Escudero, Javier·2016·Biomedical Signal Processing and Control

Abstract

Abstract Permutation entropy (PE) is a well-known and fast method extensively used in many physiological signal processing applications to measure the irregularity of time series. Multiscale PE (MPE) is based on assessing the PE for a number of coarse-grained sequences representing temporal scales. However, the stability of the conventional MPE may be compromised for short time series. Here, we propose an improved MPE (IMPE) to reduce the variability of entropy measures over long temporal scales, leading to more reliable and stable results. We gain insight into the dependency of MPE and IMPE on several straightforward signal processing concepts which appear in biomedical activity via a set of synthetic signals. We also apply these techniques to real biomedical signals via publicly available electroencephalogram (EEG) recordings acquired with eyes open and closed and to ictal and non-ictal intracranial EEGs. We conclude that IMPE improves the reliability of the entropy estimations in comparison with the traditional MPE and that it is a promising technique to characterize physiological changes affecting several temporal scales. We provide the source codes of IMPE and the synthetic data in the public domain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bspc.2015.08.004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 177

Metadata

Authors
Azami, H., & Escudero, J.
Venue
Biomedical Signal Processing and Control
Publisher
Elsevier BV
Published
2016-01
Volume
23
Pages
28-41
ISSN
1746-8094 (ISSN-L)
OpenAlex
W1512161016
Cited by
177
References
2
FWCI
6.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved multiscale permutation entropy for biomedical signal analysis: Interpretation and application to electroencephalogram recordings. https://app.cochat.ai/papers/10.1016/j.bspc.2015.08.004
The paper
Azami, H., & Escudero, J. (2016). Improved multiscale permutation entropy for biomedical signal analysis: Interpretation and application to electroencephalogram recordings. Biomedical Signal Processing and Control. https://doi.org/10.1016/j.bspc.2015.08.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.