The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Airborne microbiological characteristics in public buildings of Korea
Open accessAbstract
Abstract Characteristics of airborne bacteria and fungi were surveyed in the public buildings regulated in Korea, with the six-stage cascade impactor. The total concentrations of airborne bacteria and fungi were averaged to 404 and 382 cfu m−3 in hospital, 931 and 536 cfu m−3 in kindergarten, 294 and 334 cfu m−3 in elderly welfare facility, and 586 and 371 cfu m−3 in postpartum nurse center. Mean respirable concentrations of airborne bacteria and fungi were 194 and 292 cfu m−3 in hospital, 358 and 347 cfu m−3 in kindergarten, 134 and 266 cfu m−3 in elderly welfare facility, and 254 and 289 cfu m−3 in postpartum nurse center, respectively. Based on this results, total and respirable concentrations of airborne bacteria and fungi were significantly highest in kindergarten and lowest in elderly welfare facility ( p 0.05 ). The ratios of indoor and outdoor concentration for airborne bacteria and fungi were below 1.0 in all the investigated public buildings regardless of size distribution. The dominant genera identified in the public buildings were Staphylococcus spp., Micrococcus spp., Corynebacterium spp., and Bacillus spp., for airborne bacteria and Penicillium spp., Cladosporium spp., and Aspergillus spp., for airborne fungi, respectively. Size distributions of airborne bacteria and fungi in terms of the dominant genera were not observed consistently except for Staphylococcus spp., which was detected mainly on the first stage (>7.0 μm) and second stage(4.7–7.0 μm), and Penicillium spp., and Cladosporium spp., showing the highest collection rate at stage 3 (3.3–4.7 μm) regardless of the kind of the public buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Significance of air humidity and air velocity for fungal spore release into the air
Pasanen, A.-L., Pasanen, P., Jantunen, M. J., & Kalliokoski, P. (1991) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(91)90316-y · Cited by 191
Effect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170
Characterizing Mold Problem Buildings - Concentrations And Flora Of Viable Fungi
Hyvarinen, A., Reponen, T., Husman, T., Ruuskanen, J., & Nevalainen, A. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00017.x · Cited by 95
Cited by
Fungal pollution of indoor environments and its management
Haleem Khan, A. A., & Mohan Karuppayil, S. (2012) · Saudi Journal of Biological Sciences · doi:10.1016/j.sjbs.2012.06.002 · Cited by 292
Metadata
- Authors
- Kim, K. Y., & Kim, C. N.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2007-05
- Volume
- 42
- Issue
- 5
- Pages
- 2188-2196
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2084054965
- Cited by
- 174
- References
- 3
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Airborne microbiological characteristics in public buildings of Korea. https://app.cochat.ai/papers/10.1016/j.buildenv.2006.04.013
- The paper
- Kim, K. Y., & Kim, C. N. (2007). Airborne microbiological characteristics in public buildings of Korea. Building and Environment. https://doi.org/10.1016/j.buildenv.2006.04.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.