The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Airflow assessment in cross-ventilated buildings with operable façade elements
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
95/04308 Handbook of hydraulic resistance
(1995) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(95)95890-h · Cited by 1,420
Building ventilation: theory and measurement
(1997) · Choice Reviews Online · doi:10.5860/choice.35-2135 · Cited by 734
Man, Climate, and Architecture
Lee, D. H. K., & Givoni, B. (1971) · Geographical Review · doi:10.2307/214009 · Cited by 669
Effect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
van Hooff, T., & Blocken, B. (2010) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2009.07.008 · Cited by 427
A hybrid digital particle tracking velocimetry technique
Cowen, E. A., Monismith, S. G., Cowen, E. A., & Monismith, S. G. (1997) · Experiments in Fluids · doi:10.1007/s003480050038 · Cited by 387
Givoni, B. (1969) · Cited by 241
van Hooff, T., & Blocken, B. J. E. (2010) · Computers & Fluids · doi:10.1016/j.compfluid.2010.02.004 · Cited by 213
Kato, S., Murakami, S., Mochida, A., Akabayashi, S.-I., & Tominaga, Y. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90049-g · Cited by 145
Cited by
Blocken, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.015 · Cited by 1,163
Ramponi, R., & Blocken, B. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.01.004 · Cited by 555
LES over RANS in building simulation for outdoor and indoor applications: A foregone conclusion?
Blocken, B. (2018) · Building Simulation · doi:10.1007/s12273-018-0459-3 · Cited by 543
van Hooff, T., Blocken, B., & Tominaga, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.12.019 · Cited by 391
Urban Physics: Effect of the micro-climate on comfort, health and energy demand
Moonen, P., Defraeye, T., Dorer, V., Blocken, B., & Carmeliet, J. (2012) · Frontiers of Architectural Research · doi:10.1016/j.foar.2012.05.002 · Cited by 379
Metadata
- Authors
- Karava, P., Stathopoulos, T., & Athienitis, A. K.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 46
- Issue
- 1
- Pages
- 266-279
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2078217882
- Cited by
- 261
- References
- 20
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Airflow assessment in cross-ventilated buildings with operable façade elements. https://app.cochat.ai/papers/10.1016/j.buildenv.2010.07.022
- The paper
- Karava, P., Stathopoulos, T., & Athienitis, A. K. (2011). Airflow assessment in cross-ventilated buildings with operable façade elements. Building and Environment. https://doi.org/10.1016/j.buildenv.2010.07.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.