The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Experimental investigation of the human convective boundary layer in a quiescent indoor environment
Open accessAbstract
This study aims to characterize human convective boundary layer (CBL) in a quiescent indoor environment. The study has two objectives: first, to characterize the velocity field around the thermal manikin under two ambient temperatures and body postures; and secondly, the influence of clothing insulation/design, chair design, table positioning and seated body inclination on airflow characteristics in the breathing zone of a sitting manikin is examined. The increase of the ambient temperature from 20 to 26 °C widens the CBL flow in front of the sitting manikin but do not influence the shape of the CBL in front of the standing manikin. The same temperature increase causes the reduction of the CBL mean peak velocity from 0.24 to 0.16 m/s in front of the sitting manikin. Dressing the nude manikin with thin-tight clothing ensemble reduces the peak velocity in the breathing zone from 0.205 m/s by 17%, and by 40% for thick-loose ensemble. Removing the wig increases the peak velocity from 0.17 to 0.187 m/s. Clothing and chair design have a minor influence on the velocity profile beyond 5 cm distance from the body. Closing the gap between the table and the manikin reduces the peak velocity from 0.17 to 0.111 m/s. Manikin leaned backwards induces the peak velocity of 0.185 m/s, which is 45% above the case when manikin is leaned forward. PIV measurements complemented with Pseudo color visualization (PCV) technique provide a good synergy between quantitative and qualitative airflow characteristics and can be adequately employed for the CBL investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Cited by
Mittal, R., Ni, R., & Seo, J.-H. (2020) · Journal of Fluid Mechanics · doi:10.1017/jfm.2020.330 · Cited by 494
Tham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Self-citationAirborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Ai, Z. T., & Melikov, A. K. (2018) · Indoor Air · doi:10.1111/ina.12465 · Cited by 278
Self-citationThermal comfort of heterogeneous and dynamic indoor conditions — An overview
Mishra, A. K., Loomans, M. G. L. C., & Hensen, J. L. M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.016 · Cited by 167
Human convective boundary layer and its interaction with room ventilation flow
Licina, D., Melikov, A., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12120 · Cited by 104
Self-citation
Metadata
- Authors
- Licina, D., Pantelic, J., Melikov, A., Sekhar, C., & Tham, K. W.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2014-05
- Volume
- 75
- Pages
- 79-91
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2020095872
- Cited by
- 167
- References
- 1
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.