The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
CFD and wind-tunnel analysis of outdoor ventilation in a real compact heterogeneous urban area: Evaluation using “air delay”
Open accessAbstract
Outdoor urban ventilation in a real complex urban area is investigated by introducing a new ventilation indicator – the “air delay”. Computational Fluid Dynamics (CFD) simulations are performed using the 3D steady Reynolds-Averaged Navier-Stokes (RANS) and Large Eddy Simulation (LES) approaches. The up-to-date literature shows the lack of detailed evaluations of the two approaches for real compact urban areas. This study further presents a systematic evaluation of steady RANS and LES for the assessment of the ventilation conditions in a dense district in Nicosia, Cyprus. The ventilation conditions within the urban area are investigated by calculating the distribution of the age of air. To better assess the outdoor ventilation, a new indicator, the “air delay” is introduced as the difference between the local mean age of air at an urban area and that in an empty domain with the same computational settings, allowing the comparison of the results in different parts of the domain, without impact of the boundary conditions. CFD results are validated using wind-tunnel measurements of mean wind speed and turbulence intensity performed for the same urban area. The results show that LES can accurately predict the mean wind speed and turbulence intensity with the average deviations of about 6% and 14%, respectively, from the wind-tunnel measurements while for the steady RANS, these are 8% and 31%, respectively. The steady RANS simulations overestimate the local mean air delay. The deviation between the two approaches is 52% at pedestrian level (2 m).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new k-ε eddy viscosity model for high Reynolds number turbulent flows
Shih, T.-H., Liou, W. W., Shabbir, A., Yang, Z., & Zhu, J. (1995) · Computers & Fluids · doi:10.1016/0045-7930(94)00032-t · Cited by 6,119
A proposed modification of the Germano subgrid–scale closure method
Lilly, D. K. (1992) · Physics of Fluids A: Fluid Dynamics · doi:10.1063/1.858280 · Cited by 4,077
Cited by
LES over RANS in building simulation for outdoor and indoor applications: A foregone conclusion?
Blocken, B. (2018) · Building Simulation · doi:10.1007/s12273-018-0459-3 · Cited by 543
Self-citation
Metadata
- Authors
- Antoniou, N., Montazeri, H., Wigo, H., Neophytou, M. K.-A., Blocken, B., & Sandberg, M.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 126
- Pages
- 355-372
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2763574531
- Cited by
- 176
- References
- 2
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CFD and wind-tunnel analysis of outdoor ventilation in a real compact heterogeneous urban area: Evaluation using “air delay”. https://app.cochat.ai/papers/10.1016/j.buildenv.2017.10.013
- The paper
- Antoniou, N., Montazeri, H., Wigo, H., Neophytou, M. K.-A., Blocken, B., & Sandberg, M. (2017). CFD and wind-tunnel analysis of outdoor ventilation in a real compact heterogeneous urban area: Evaluation using “air delay”. Building and Environment. https://doi.org/10.1016/j.buildenv.2017.10.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.