CoChat

Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings

Open access
Salthammer, Tunga · 2019 · Building and Environment
Cited by 245

The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.

Abstract

A literature study was carried out with respect to the release and accumulation of formaldehyde indoors. With reference to representative emission data, exposure scenarios were calculated on the basis of the European Reference Room with the aid of Monte-Carlo methods. Furthermore, data concerning formaldehyde concentrations in indoor and outdoor air, as well as data on air exchange, were collected for the European region. Various permanent, intermitting and temporary emission sources were compared under the specified conditions of the Reference Room. It was thereby necessary to bear in mind that, for example, the emission tests for raw wood-based materials and mineral wool do not take place under realistic conditions, as these products are not applied open in indoor areas. It is demonstrated that coatings and coverings drastically reduce the release of formaldehyde into the room air. Moreover, it becomes clear that the Reference Room concept allows a comparison of emission sources but also greatly overestimates the formaldehyde concentrations in indoor areas when diverse sources are simply added together. In view of the discussed aspects, as well as taking into account outdoor air conditions and diverse secondary sources, the potential problem of exposure to high formaldehyde concentrations in indoor areas can therefore not be solved through the further tightening of already existing regulations, in particular because peak concentrations and therefore high exposures would remain largely uninfluenced. Due to the fact that formaldehyde is a compound with a threshold effect, this aspect is of considerable importance. Consequently, an appropriate risk management option would be to primarily address the peak concentrations originating from temporary and intermitting sources.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2018.12.042

Cites

106 of 106 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 106 references

Cited by

See all 245

Metadata

Authors
Salthammer, T.
Venue
Building and Environment
Publisher
Elsevier BV
Published
2019-03
Volume
150
Pages
219-232
ISSN
0360-1323 (ISSN-L)
OpenAlex
W2906179696
Cited by
245
References
106
FWCI
8.51
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings. https://app.cochat.ai/papers/10.1016/j.buildenv.2018.12.042
The paper
Salthammer, T. (2019). Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings. Building and Environment. https://doi.org/10.1016/j.buildenv.2018.12.042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.