Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Towards optimal control of air handling units using deep reinforcement learning and recurrent neural network

Zou, Zhengbo, Yu, Xinran, Ergan, Semiha · 2020 · Building and Environment

Abstract

Abstract Optimal control of heating, ventilation and air conditioning systems (HVACs) aims to minimize the energy consumption of equipment while maintaining the thermal comfort of occupants. Traditional rule-based control methods are not optimized for HVAC systems with continuous sensor readings and actuator controls. Recent developments in deep reinforcement learning (DRL) enabled control of HVACs with continuous sensor inputs and actions, while eliminating the need of building complex thermodynamic models. DRL control includes an environment, which approximates real-world HVAC operations; and an agent, that aims to achieve optimal control over the HVAC. Existing DRL control frameworks use simulation tools (e.g., EnergyPlus) to build DRL training environments with HVAC systems information, but oversimplify building geometrics. This study proposes a framework aiming to achieve optimal control over Air Handling Units (AHUs) by implementing long-short-term-memory (LSTM) networks to approximate real-world HVAC operations to build DRL training environments. The framework also implements state-of-the-art DRL algorithms (e.g., deep deterministic policy gradient) for optimal control over the AHUs. Three AHUs, each with two-years of building automation system (BAS) data, were used as testbeds for evaluation. Our LSTM-based DRL training environments, built using the first year's BAS data, achieved an average mean square error of 0.0015 across 16 normalized AHU parameters. When deployed in the testing environments, which were built using the second year's BAS data of the same AHUs, the DRL agents achieved 27%–30% energy saving comparing to the actual energy consumption, while maintaining the predicted percentage of discomfort (PPD) at 10%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.buildenv.2019.106535

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 188

Metadata

Authors
Zou, Z., Yu, X., & Ergan, S.
Venue
Building and Environment
Publisher
Elsevier BV
Published
2020-01
Volume
168
Pages
106535
ISSN
0360-1323 (ISSN-L)
OpenAlex
W2989354373
Cited by
188
References
5
FWCI
9.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Towards optimal control of air handling units using deep reinforcement learning and recurrent neural network. https://app.cochat.ai/papers/10.1016/j.buildenv.2019.106535
The paper
Zou, Z., Yu, X., & Ergan, S. (2020). Towards optimal control of air handling units using deep reinforcement learning and recurrent neural network. Building and Environment. https://doi.org/10.1016/j.buildenv.2019.106535

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.