The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-efficiency electromagnetic interference shielding realized in nacre-mimetic graphene/polymer composite with extremely low graphene loading
Abstract
Abstract Electromagnetic interference (EMI) shielding performance of composites are usually limited by their electrical conductivity and permeability, which largely depend on the conductive filler content, aspect ratio, magnetic permeability, etc. Higher filler content usually leads to high cost, poor dispersion and easy agglomeration, making the polymer composites mechanically brittle and difficult to process. Therefore, it is highly desirable to develop composite with low conductive filler content while maintaining its high EMI shielding performance. Here, in our work a high-performance EMI shielding was realized in nacre-mimetic graphene/polymer composites with extremely low graphene loading. A nacre-mimetic 3D conductive graphene network with biaxial aligned lamellar structure was prepared by a unique bidirectional freezing technique. With such a nacre-mimetic, highly aligned network, our graphene/polymer composites exhibit anisotropic conductivities, mechanical properties and therefore remarkable EMI shielding effectiveness at an extremely low graphene content. Specifically, the biomimetic composites with 0.42 wt% graphene content shows an enhanced EMI shielding effectiveness of ∼65 dB after annealing the graphene aerogels at 2500 °C, which is comparable to the copper foil. More remarkably, as the composite is low in density, its specific shielding effectiveness is even higher than that of metal foils and solid materials with high conductive filler content.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mesoscale assembly of chemically modified graphene into complex cellular networks
Barg, S., Perez, F. M., Ni, N., do Vale Pereira, P., Maher, R. C., Garcia-Tuñon, E., Eslava, S., Agnoli, S., Mattevi, C., & Saiz, E. (2014) · Nature Communications · doi:10.1038/ncomms5328 · Cited by 285
Cited by
Xia, Y., Gao, W., & Gao, C. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204591 · Cited by 734
Self-citationRecent Progress in Graphene/Polymer Nanocomposites
Sun, X., Huang, C., Wang, L., Liang, L., Cheng, Y., Fei, W., & Li, Y. (2021) · Advanced Materials · doi:10.1002/adma.202001105 · Cited by 490
Progress in polymers and polymer composites used as efficient materials for EMI shielding
Kruželák, J., Kvasničáková, A., Hložeková, K., & Hudec, I. (2021) · Nanoscale Advances · doi:10.1039/d0na00760a · Cited by 421
Chen, Y., Yang, Y., Xiong, Y., Zhang, L., Xu, W., Duan, G., Mei, C., Jiang, S., Rui, Z., & Zhang, K. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101204 · Cited by 258
Metadata
- Authors
- Gao, W., Zhao, N., Yu, T., Xi, J., Mao, A., Yuan, M., Bai, H., & Gao, C.
- Venue
- Carbon
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 157
- Pages
- 570-577
- ISSN
- 0008-6223 (ISSN-L)
- OpenAlex
- W2982017822
- Cited by
- 218
- References
- 1
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-efficiency electromagnetic interference shielding realized in nacre-mimetic graphene/polymer composite with extremely low graphene loading. https://app.cochat.ai/papers/10.1016/j.carbon.2019.10.051
- The paper
- Gao, W., Zhao, N., Yu, T., Xi, J., Mao, A., Yuan, M., Bai, H., & Gao, C. (2020). High-efficiency electromagnetic interference shielding realized in nacre-mimetic graphene/polymer composite with extremely low graphene loading. Carbon. https://doi.org/10.1016/j.carbon.2019.10.051
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.