The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Graphene and metal organic frameworks (MOFs) hybridization for tunable chemoresistive sensors for detection of volatile organic compounds (VOCs) biomarkers
Abstract
Abstract The paper presents the tuning of sensitivity and selectivity performance of volatile organic compounds (VOCs) chemoresistive sensors for biomarker detection using the hybridization of pristine graphene (pG) and metal organic frameworks (MOFs). The synergistic effect of this nanocomposite material was discovered showing improved sensing performances where graphene acts as a highly conductive sensing element, and MOFs, with a high surface area and adsorption capacity provide an enhanced sensitivity and selectivity for specific VOCs. By combining and selecting different MOFs, we proposed that is possible to tailor sensing performances of chemoresistive sensors for VOC biomarkers detection. To prove that graphene hybrid nanocomposite with selected MOFs including copper–benzene-1,3,5-tricarboxylate (pG-Cu BTC), zirconium 1,4-dicarboxybenzene (pG-UiO 66) and 2-methylimidazole zinc salt (pG-ZIF 8), were investigated to enhance the sensing performance and capability of distinguishing different VOC biomarkers (e.g., methanol, ethanol, chloroform, acetone, acetonitrile and THF). Results showed that the pG-Cu BTC sensor has the highest sensitivity and selectivity towards chloroform and methanol VOCs at 2.82–22.6 ppm level. The proposed concept presents a valuable contribution for the development of low-cost and high-performing VOC biomarker sensors for monitoring human health from metabolic human breath and further implementation for non-invasive biomedical diagnostics for personalized telehealth monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Jayaramulu, K., Mukherjee, S., Morales, D. M., Dubal, D. P., Nanjundan, A. K., Schneemann, A., Masa, J., Kment, S., Schuhmann, W., Otyepka, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00270 · Cited by 431
MOF‐Based Chemiresistive Gas Sensors: Toward New Functionalities
Jo, Y., Jo, Y. K., Lee, J., Jang, H. W., Hwang, I., & Yoo, D. J. (2023) · Advanced Materials · doi:10.1002/adma.202206842 · Cited by 410
Metadata
- Authors
- Tung, T. T., Tran, M. T., Feller, J.-F., Castro, M., Van Ngo, T., Hassan, K., Nine, M. J., & Losic, D.
- Venue
- Carbon
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 159
- Pages
- 333-344
- ISSN
- 0008-6223 (ISSN-L)
- OpenAlex
- W2995345816
- Cited by
- 159
- References
- 1
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphene and metal organic frameworks (MOFs) hybridization for tunable chemoresistive sensors for detection of volatile organic compounds (VOCs) biomarkers. https://app.cochat.ai/papers/10.1016/j.carbon.2019.12.010
- The paper
- Tung, T. T., Tran, M. T., Feller, J.-F., Castro, M., Van Ngo, T., Hassan, K., Nine, M. J., & Losic, D. (2020). Graphene and metal organic frameworks (MOFs) hybridization for tunable chemoresistive sensors for detection of volatile organic compounds (VOCs) biomarkers. Carbon. https://doi.org/10.1016/j.carbon.2019.12.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.