The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antifreezing and stretchable all-gel-state supercapacitor with enhanced capacitances established by graphene/PEDOT-polyvinyl alcohol hydrogel fibers with dual networks
Abstract
Abstract Although aqueous fibrous supercapacitor is one of the most advantageous energy storage devices for powering wearable electronics due to its excellent flexibility, outstanding cycling stability and high safety, it is still a challenge for its electroactive components to be cold-tolerant and stretchable for adapting fluctuating climate environments. Herein, a graphene/PEDOT:PSS hydrogel fiber with a continuous rose flower-like network is firstly constructed, and an antifreezing polyvinyl alcohol (PVA) network is subsequently taken into the hydrogel fiber via solvent replacement to generate an antifreezing and stretchable graphene/PEDOT-PVA hydrogel fiber with dual networks. Benefiting from superior interface compatibility of the hydrogel fiber with a PVA electrolyte, the assembled all-gel-state supercapacitor delivers a high capacitance of 281.2 F g−1 (0.1 A g−1) at 25 °C, more than twice higher than that of an aerogel fiber-based supercapacitor. Furthermore, this supercapacitor exhibits stable subzero-temperature electrochemical performances due to the smooth ion-transport channels and good conductivity of the antifreezing hydrogel fiber electrode, evidenced by the high specific capacitance of 212.6 F g−1 and the excellent capacitance retention of 91% after 5000 charge/discharge cycles at −20 °C. Finally, a highly stretchable spring-like supercapacitor exhibits an excellent capacitance retention of 92% after 5000 stretching cycles at a strain of 500%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Cited by
Liu, H., Xu, T., Cai, C., Liu, K., Liu, W., Zhang, M., Du, H., Si, C., & Zhang, K. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202113082 · Cited by 571
Self-citationXu, T., Song, Q., Liu, K., Liu, H., Pan, J., Liu, W., Dai, L., Zhang, M., Wang, Y., Si, C., et al. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01073-x · Cited by 435
Self-citationXu, T., Liu, K., Sheng, N., Zhang, M., Liu, W., Liu, H., Dai, L., Zhang, X., Si, C., Du, H., et al. (2022) · Energy Storage Materials · doi:10.1016/j.ensm.2022.03.013 · Cited by 430
Self-citationSahoo, S., Kumar, R., Joanni, E., Singh, R. K., & Shim, J.-J. (2022) · Journal of Materials Chemistry A · doi:10.1039/d2ta02357a · Cited by 337
Dong, W., Xie, M., Zhao, S., Qin, Q., & Huang, F. (2023) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2022.100713 · Cited by 319
Metadata
- Authors
- Xu, T., Yang, D., Zhang, S., Zhao, T., Zhang, M., & Yu, Z.-Z.
- Venue
- Carbon
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 171
- Pages
- 201-210
- ISSN
- 0008-6223 (ISSN-L)
- OpenAlex
- W3082456111
- Cited by
- 176
- References
- 1
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antifreezing and stretchable all-gel-state supercapacitor with enhanced capacitances established by graphene/PEDOT-polyvinyl alcohol hydrogel fibers with dual networks. https://app.cochat.ai/papers/10.1016/j.carbon.2020.08.071
- The paper
- Xu, T., Yang, D., Zhang, S., Zhao, T., Zhang, M., & Yu, Z.-Z. (2021). Antifreezing and stretchable all-gel-state supercapacitor with enhanced capacitances established by graphene/PEDOT-polyvinyl alcohol hydrogel fibers with dual networks. Carbon. https://doi.org/10.1016/j.carbon.2020.08.071
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.