CoChat

Autonomic modulation of electrical restitution, alternans and ventricular fibrillation initiation in the isolated heart

Ng, G. André, Brack, Kieran E., Patel, Vanlata H., Coote, John H. · 2007 · Cardiovascular Research
Cited by 203

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Abnormal autonomic nerve activity is a strong prognostic marker for ventricular arrhythmias but the mechanisms underlying the autonomic modulation of ventricular fibrillation (VF) initiation are poorly understood. We examined the effects of direct sympathetic (SS) and vagus (VS) nerve stimulation on electrical restitution, alternans and VF threshold (VFT) in a novel isolated rabbit heart preparation with intact dual autonomic innervation. METHODS: Monophasic Action Potentials (MAPs) were recorded from a left ventricular epicardial site on innervated, isolated rabbit hearts (n=16). Standard restitution, effective refractory period (ERP), electrical alternans and VFT were measured at baseline and during SS and VS separately. RESULTS: The restitution curve was shifted downwards and made steeper with SS whilst VS caused an upward shift and a flattening of the curve. The maximum slope of restitution was increased from 1.30+/-0.10 at baseline to 1.86+/-0.17 (by 45+/-12%, P<0.01) with SS and decreased to 0.69+/-0.10 (by 51+/-6%, P<0.001) with VS. ERP was decreased from 127.3+/-2.5 ms to 111.8+/-1.8 ms with SS (by 12+/-2%, P<0.001) and increased to 144.0+/-2.2 ms with VS (by 13+/-2%, P<0.001). VFT was decreased from 4.7+/-0.6 mA to 1.9+/-0.5 mA with SS (by 64+/-5%, P<0.001) and increased to 8.7+/-1.1 mA with VS (by 89+/-14%, P<0.0005). There was a significant inverse relationship between the maximum slope of restitution and VFT (r=-0.63, P<0.0001). When compared with baseline, SS caused electrical alternans at longer pacing cycle lengths (139.0+/-8.4 vs. 123.0+/-7.8 ms, P<0.01) with greater degree of alternans (32.5+/-9.9 vs. 15.4+/-3.2%, P<0.05). It also caused a wider range of cycle lengths where alternans occurred (53.0+/-6.2 vs. 41.0+/-7.0 ms, P<0.05) whilst vagus nerve stimulation shortened this range (33.0+/-7.3 ms, P<0.001). CONCLUSIONS: Sympathetic stimulation increased maximum slope of restitution and electrical alternans but decreased ERP and VF threshold whilst vagus nerve stimulation had opposite effects. The interaction between action potential duration and beat-to-beat interval may play an important role in the autonomic modulation of VF initiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cardiores.2006.12.001

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 203

Metadata

Authors
Ng, G. A., Brack, K. E., Patel, V. H., & Coote, J. H.
Venue
Cardiovascular Research
Published
2007-03-01
Volume
73
Issue
4
Pages
750-760
ISSN
  • 0008-6363 (ISSN-L)
  • 1755-3245
OpenAlex
W2142100237
Cited by
203
References
3
FWCI
2.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Autonomic modulation of electrical restitution, alternans and ventricular fibrillation initiation in the isolated heart. https://app.cochat.ai/papers/10.1016/j.cardiores.2006.12.001
The paper
Ng, G. A., Brack, K. E., Patel, V. H., & Coote, J. H. (2007). Autonomic modulation of electrical restitution, alternans and ventricular fibrillation initiation in the isolated heart. Cardiovascular Research. https://doi.org/10.1016/j.cardiores.2006.12.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.