CoChat

Comparison of hemostasis times with a chitosan-based hemostatic pad (Clo-SurPlus Radial™) vs. mechanical compression (TR Band®) following transradial access: A pilot study

Roberts, Jonathan S., Niu, Jianli, Pastor-Cervantes, Juan A. · 2019 · Cardiovascular Revascularization Medicine
Cited by 28

The DOI matches its Crossref record.

Abstract

BACKGROUND Hemostasis following transradial arterial access (TRA) is usually achieved by mechanical compression. This study investigated if use of a chitosan-based hemostatic pad (Clo-SurPlus Radial™) combined with mechanical compression (TR Band®) could shorten hemostasis time after TRA, compared with a TR Band® alone. METHODS 40 patients undergoing cardiac catheterization and/or percutaneous coronary intervention were assigned into 4 cohorts post TRA: 10 patients received mechanical compression with a TR Band® alone for 120 min. The other 30 patients received compression with a Clo-SurPlus Radial™ pad combined with a TR Band® for 60 min, 45 min, and 30 min, respectively (n = 10/per cohort). Times to hemostasis and access-site complications were recorded. RESULTS There were no differences in patient characteristics, mean dose of heparin, or mean activated clotting time value at the end of procedure among the four cohorts. Median time to hemostasis with the TR Band® alone was 120.5 min versus 60 min, 45 min and 30 min for the 60-min, 45-min, and 30-min Clo-SurPlus Radial™ pad combined with the TR Band® cohorts, respectively. No radial artery occlusion, late rebleeding nor hematoma was noted in this series of patients. CONCLUSIONS In this pilot trial, use of a Clo-SurPlus Radial™ pad in combination with a TR band® significantly shortened hemostasis time, as compared to a TR band® alone, with no increased complications noted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.carrev.2018.11.026

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 12

  1. Andò, 2016, Radial access reduces mortality in patients with acute coronary syndromes: results from an updated trial sequential analysis of randomized trials, JACC Cardiovasc Interv, 9, 660, 10.1016/j.jcin.2015.12.008 · DOI
  2. Rao, 2016, Arterial access and arteriotomy site closure devices, Nat Rev Cardiol, 13, 641, 10.1038/nrcardio.2016.133 · DOI
  3. Pancholy, 2009, Impact of two different hemostatic devices on radial artery outcomes after transradial catheterization, J Invasive Cardiol, 21, 101
  4. Dai, 2015, A comparison of 2 devices for radial artery hemostasis after transradial coronary intervention, J Cardiovasc Nurs, 30, 192, 10.1097/JCN.0000000000000115 · DOI
  5. Barbeau, 2004, Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients, Am Heart J, 147, 489, 10.1016/j.ahj.2003.10.038 · DOI · Paper page
  6. Roberts, 2017, Comparison of hemostasis times with a kaolin-based hemostatic pad (QuikClot radial) vs mechanical compression (TR band) following Transradial access: a pilot prospective study, J Invasive Cardiol, 29, 328
  7. Seto, 2018, Radial hemostasis is facilitated with a potassium ferrate hemostatic patch: the Statseal with TR band assessment trial (STAT), EuroIntervention, 10.4244/EIJ-D-18-00101 · doi:10.4244/eij-d-18-00101
  8. Balzer, 2007, Postinterventional percutaneous closure of femoral artery access sites using the Clo-Sur PAD device: initial findings, Eur Radiol, 17, 693, 10.1007/s00330-006-0279-1 · DOI
  9. Kang, 2017, Hemostasis pad combined with compression device after transradial coronary procedures: a randomized controlled trial, PLoS One, 12, 10.1371/journal.pone.0181099 · DOI
  10. Pancholy, 2012, Effect of duration of hemostatic compression on radial artery occlusion after transradial access, Catheter Cardiovasc Interv, 79, 78
  11. Dangoisse, 2017, Am J Cardiol, 120, 374, 10.1016/j.amjcard.2017.04.037 · doi:10.1016/j.amjcard.2017.04.037
  12. Rashid, 2016, Radial artery occlusion after transradial interventions: a systematic review and meta-analysis, J Am Heart Assoc, 5, 10.1161/JAHA.115.002686 · DOI · Paper page

Cited by

Metadata

Authors
Roberts, J. S., Niu, J., & Pastor-Cervantes, J. A.
Venue
Cardiovascular Revascularization Medicine
Publisher
Elsevier BV
Published
2019-10
Volume
20
Issue
10
Pages
871-874
ISSN
1553-8389
Cited by
28
References
0
Language
en
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
Scion BioMedical, Inc.

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.