Fundamentals of ion mobility spectrometry
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Fundamental questions in ion mobility spectrometry have practical implications for analytical applications in general, and omics in particular, in three respects. (1) Understanding how ion mobility and collision cross section values depend on the collision gas, on the electric field and on temperature is crucial to ascertain their transferability across instrumental platforms. (2) Predicting collision cross section values for new analytes is necessary to exploit the full potential of ion mobility in discovery workflows. (3) Finally, understanding the fate of ion structures in the gas phase is essential to infer meaningful information on solution structures based on gas-phase ion mobility measurements. We review here the most recent advances in ion mobility fundamentals, relevant to these three aspects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Carbon cluster cations with up to 84 atoms: structures, formation mechanism, and reactivity
von Helden, G., Hsu, M. T., Gotts, N., & Bowers, M. T. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100133a011 · Cited by 593
High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
Guevremont, R. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.119 · Cited by 444
May, J. C., Goodwin, C. R., Lareau, N. M., Leaptrot, K. L., Morris, C. B., Kurulugama, R. T., Mordehai, A., Klein, C., Barry, W., Darland, E., et al. (2014) · Analytical Chemistry · doi:10.1021/ac4038448 · Cited by 401
Campuzano, I., Bush, M. F., Robinson, C. V., Beaumont, C., Richardson, K., Kim, H., & Kim, H. I. (2012) · Analytical Chemistry · doi:10.1021/ac202625t · Cited by 383
Cited by
Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
“The ions are subjected to varying E/N, with peak values reaching 50–160 Td (Giles et al., 2010; Gabelica & Marklund, 2018).”
Self-citationPerez de Souza, L., Alseekh, S., Scossa, F., & Fernie, A. R. (2021) · Nature Methods · doi:10.1038/s41592-021-01116-4 · Cited by 358
Collision cross section compendium to annotate and predict multi-omic compound identities
Picache, J. A., Rose, B. S., Balinski, A., Leaptrot, K. L., Sherrod, S. D., May, J. C., & McLean, J. A. (2019) · Chemical Science · doi:10.1039/c8sc04396e · Cited by 279
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Ion Mobility Spectrometry in Food Analysis: Principles, Current Applications and Future Trends
Hernández-Mesa, M., Ropartz, D., García-Campaña, A. M., Rogniaux, H., Dervilly-Pinel, G., & Le Bizec, B. (2019) · Molecules · doi:10.3390/molecules24152706 · Cited by 202
“fields (E/N > 4–10 Townsends (Td); 1 Td = 10−21 V m2) and Equation (3) is no longer applicable [10].”
BackgroundInfluentialPerez De Souza, L., Alseekh, S., Brotman, Y., & Fernie, A. R. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1766975 · Cited by 145
“This technique is still not often integrated within well-established metabolomics platforms, but it is quickly growing in popularity due to its complementarity to traditional LC-MS systems [125].”
BackgroundIon Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
Allison, T. M., Barran, P., Cianférani, S., Degiacomi, M. T., Gabelica, V., Grandori, R., Marklund, E. G., Menneteau, T., Migas, L. G., Politis, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05791 · Cited by 38
Self-citationTurzo, S. M. B. A., Seffernick, J. T., Lyskov, S., & Lindert, S. (2023) · Briefings in Bioinformatics · doi:10.1093/bib/bbad308 · Cited by 13
Wang, X., Norgate, E., Dai, J., Benoit, F., Bristow, T., England, R. M., Kalapothakis, J. M. D., & Barran, P. E. (2025) · Nature Communications · doi:10.1038/s41467-025-59065-x · Cited by 7
Metadata
- Authors
- Gabelica, V., & Marklund, E.
- Venue
- Current Opinion in Chemical Biology
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 42
- Pages
- 51-59
- ISSN
- 1367-5931 (ISSN-L)
- OpenAlex
- W2755377387
- Cited by
- 440
- References
- 74
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.