Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?

Campuzano, Iain DG, Lippens, Jennifer L·2018·Current Opinion in Chemical Biology

Abstract

Over the past decade ion mobility (IM) coupled with mass spectrometry (MS) has emerged as a wide spread analytical technique, utilized in research areas ranging from small molecule to proteins analyzed under native-MS and solution conditions. The ion-neutral collision cross section (Ω) derived from an IM experiment can be used to make inferences about the ion's size, shape and charge distribution, when compared to molecular dynamic (MD) or quantum mechanically (QM) derived candidate structures. IM can also be used as an orthogonal separation technique when coupled with liquid chromatographic (LC) separations. IM has been readily adopted by academic research groups and has been demonstrated to be highly enabling, resulting in the inception of completely new research areas, such as gas-phase structural biology. The same cannot be said for IM in pharma, where it is still perceived as a standalone, research-only based analytical tool. Herein, we will describe key innovations of IM instrumentation by current MS vendors and IMs application within academic and pharmaceutical research and how these developments have been, and can be applied to research discovery efforts within the pharmaceutical industry.

Integrity signals

Registry

Crossref · 10.1016/j.cbpa.2017.11.008

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 126 · Cited by 42

Authors
Campuzano, I. D., & Lippens, J. L.
Affiliations
Amgen (United States) (US)
Corresponding author
Campuzano, Iain DG
Venue
Current Opinion in Chemical Biology
Publisher
Elsevier BV
Published
2018-02
Volume
42
Pages
147-159
ISSN
1367-5931 (ISSN-L)
OpenAlex
W2783290581
Cited by
42
References
126
Citations by year
2026: 3 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 6 · 2020: 5 · 2019: 8 · 2018: 7
FWCI
0.82
Type
journal article
Language
en
Open access
closed
Locations
  • Current Opinion in Chemical Biology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
Keywords
ion mobility spectrometry, pharmaceutical industry, drug discovery
MeSH terms
Ion Mobility Spectrometry, Chemistry, Pharmaceutical, Chromatography, Liquid, Drug Industry, Quantum Theory, Mass Spectrometry, Biophysical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review