Various calibration procedures result in optimal standardization of routinely used 25(OH)D ID-LC-MS/MS methods
Open accessAbstract
Background The variety of LC-MS/MS methods measuring total 25(OH)D used today is vast and the comparability among these methods is still not well assessed. Methods Here, we performed a comparison in samples of healthy donors between the currently routinely used 25(OH)D LC-MS/MS methods in the Netherlands and the Ghent University reference measurement procedure to address this issue (n=40). Additionally, an interlaboratory comparison in patient serum samples assessed agreement between the Dutch diagnostic methods (n=37). Results The overall correlation of the routine methods for 25(OH)D 3 with the reference measurement procedures and with the mean of all diagnostic methods was excellent (r>0.993 and r>0.989, respectively). Three out of five methods aligned perfectly with both the reference measurement procedure and the median of all methods. One of the routine methods showed a small positive bias, while another showed a small negative bias consistently in both comparisons. Conclusion The biases most probably originated from differences in calibration procedure and may be obviated by reassessing calibration of stock standards and/or calibrator matrices. In conclusion, five diagnostic centers have performed a comparison with the 25(OH)D Ghent University reference measurement procedure in healthy donor serum samples and a comparison among themselves in patient serum samples. Both analyses showed a high correlation and specificity of the routine LC-MS/MS methods, yet did reveal some small standardization issues that could not be traced back to the technical details of the different methods. Hence, this study indicates various calibration procedures can result in perfect alignment.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Serum 25(OH)D and total testosterone were measured by isotope-dilution liquid chromatography-tandem mass spectrometry and used for statistical analyses.
“Serum levels of 25(OH)D and TT were additionally measured by well-adjusted isotope-dilution liquid chromatography–tandem mass spectrometry (ID-LC–MS/MS) methods in 2018 [18, 19]. 25(OH)D and TT measured by ID-LC–MS/MS were used for statistical analyses.”
From Effects of vitamin D supplementation on androgens in men with low testosterone levels: a randomized controlled trial (2019) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- [2]Cashman KD Kiely M Kinsella M Durazo-Arvizu RA Tian L Zhang Y Evaluation of vitamin D standardization program protocols for standardizing serum 25-hydroxyvitamin D data: a case study of the program’s potential for national nutrition and health surveys Am J Clin Nutr 97 2013 1235 1242 23615829 PMC3652922
- [3]Depreter B Heijboer AC Langlois MR Accuracy of three automated 25-hydroxyvitamin D assays in hemodialysis patients Clin Chim Acta 415 2013 255 260 23159781
- [4]Farrell CJ Martin S McWhinney B Straub I Williams P Herrmann M State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods Clin Chem 58 2012 531 542 22230812
- [5]Heijboer AC Blankenstein MA Kema IP Buijs MM Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin d binding protein concentration Clin Chem 58 2012 543 548 22247500
- [6]Janssen MJ Wielders JP Bekker CC Boesten LS Buijs MM Heijboer AC Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum Steroids 77 2012 1366 1372 22925701
- [7]Keevil B Does the presence of 3-epi-25ohd3 affect the routine measurement of vitamin D using liquid chromatography tandem mass spectrometry? Clin Chem Lab Med 50 2012 181 183 22011227
- [8]Mineva EM Schleicher RL Chaudhary-Webb M Maw KL Botelho JC Vesper HW A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D(3) and 25-hydroxyvitamin D(2) using isotope-dilution liquid chromatography-tandem mass spectrometry Anal Bioanal Chem 407 2015 5615 5624 25967149 PMC4823009
- [9]Sempos CT Vesper HW Phinney KW Thienpont LM Coates PM Vitamin DSP Vitamin D status as an international issue: national surveys and the problem of standardization Scand J Clin Lab Investig Suppl 243 2012 32 40 22536760
- [10]Stepman HC Vanderroost A Van Uytfanghe K Thienpont LM Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry Clin Chem 57 2011 441 448 21248072
- [11]Tai SS Bedner M Phinney KW Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry Anal Chem 82 2010 1942 1948 20136128 PMC2838390
- [12]van den Ouweland JM Beijers AM van Daal H Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in lc-ms/ms methods not separating both metabolites as determined by an lc-ms/ms method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum J Chromatogr B Anal Technol Biomed Life Sci 967 2014 195 202 25125396
- [14]Wright MJ Halsall DJ Keevil BG Removal of 3-epi-25-hydroxyvitamin D(3) interference by liquid chromatography-tandem mass spectrometry is not required for the measurement of 25-hydroxyvitamin D(3) in patients older than 2 years Clin Chem 58 2012 1719 1720 23071364
- [15]Lensmeyer G Poquette M Wiebe D Binkley N The C-3 epimer of 25-hydroxyvitamin D(3) is present in adult serum J Clin Endocrinol Metab 97 2012 163 168 22013102
- [16]Wiebe D Binkley N Case report: three patients with substantial serum levels of 3-epi-25(OH)D including one with 3-epi-25(OH)D2 while on high-dose ergocalciferol J Clin Endocrinol Metab 2014 1117 1121 24476080 PMC3973774
Cited by
Sorted by citations
Lerchbaum, E., Trummer, C., Theiler-Schwetz, V., Kollmann, M., Wölfler, M., Heijboer, A. C., Pilz, S., & Obermayer-Pietsch, B. (2019) · European Journal of Nutrition · doi:10.1007/s00394-018-1858-z · Cited by 40 · see citing works
Self-citationFanelli, F., Cantù, M., Temchenko, A., Mezzullo, M., Lindner, J. M., Peitzsch, M., Hawley, J. M., Bruce, S., Binz, P.-A., Ackermans, M. T., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1028 · Cited by 36 · see citing works
Self-citation
- Authors
- Dirks, N. F., Vesper, H. W., van Herwaarden, A. E., van den Ouweland, J. M. W., Kema, I. P., Krabbe, J. G., & Heijboer, A. C.
- Affiliations
- Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
- Centers for Disease Control and Prevention (US)
- University Medical Center Groningen (NL)
- Medisch Spectrum Twente (NL)
- Corresponding author
- Heijboer, Annemieke C.
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 462
- Pages
- 49-54
- ISSN
- 0009-8981 (ISSN-L)
- PMC
- PMC5703036
- OpenAlex
- W2511618950
- Cited by
- 40
- References
- 0
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 7 · 2022: 4 · 2021: 6 · 2020: 3 · 2019: 6 · 2018: 8 · 2017: 3
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Clinica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (publishedVersion)
- PubMed Central (acceptedVersion)
- Pure Amsterdam UMC (submittedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
- Funders
- Dutch Foundation for Quality Assessment in Medical Laboratories
- Topics
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pathology and Forensic Medicine › Vitamin D Research Studies
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
- Keywords
- 25-hydroxyvitamin D, LC-MS/MS, method standardization, calibration method, interlaboratory comparison, reference measurement procedure, measurement bias
- MeSH terms
- Calcifediol, Calibration, Chromatography, Liquid, Humans, 25-Hydroxyvitamin D 2, Tandem Mass Spectrometry, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review