The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescent sensors for the detection of hydrazine in environmental and biological systems: Recent advances and future prospects
Abstract
Abstract Being a widely used raw material in the manufacture of synthetic catalysts, agricultural chemicals and pharmaceutical products, hydrazine (N2H4) caused irreversible pollution to air, water and soil in our environment owing to its high toxic impact and massive use. In addition, during the metabolism process of certain drugs, such as isoniazid (INH), hydrazine can also be released, causing serious harm to human body. It has been proved by previous researches that hydrazine could cause several adverse effects, including the inhibition of molecular metabolism, mitochondrial oxidation and DNA damage. Thus, methods which could sensitively and selectively detect hydrazine in vivo and in vitro are in urgent need. Fluorescent sensors, a powerful tool for efficiently evaluating the hydrazine levels in environmental and living systems with minimal perturbation, were widely studied over the past few years. Since the number of the fluorescent sensors for hydrazine detection has grown rapidly, this review attempted to present a well-organized overview of existing design strategies for developing fluorescent sensors for hydrazine, including both reaction-based sensors and material-based sensors from 2011 to the present. The molecular structures, sensing mechanisms and applications of these sensors were emphatically classified and discussed. Moreover, the following prospects and challenges of this field were also provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maeda, H., Yamamoto, K., Kohno, I., Hafsi, L., Itoh, N., Nakagawa, S., Kanagawa, N., Suzuki, K., & Uno, T. (2007) · Chemistry – A European Journal · doi:10.1002/chem.200600522 · Cited by 85
Cited by
Deng, C., Toe, C. Y., Li, X., Tan, J., Yang, H., Hu, Q., & He, C. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202201047 · Cited by 253
Metadata
- Authors
- Zhang, X.-Y., Yang, Y.-S., Wang, W., Jiao, Q.-C., & Zhu, H.-L.
- Venue
- Coordination Chemistry Reviews
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 417
- Pages
- 213367
- ISSN
- 0010-8545 (ISSN-L)
- OpenAlex
- W3021683238
- Cited by
- 218
- References
- 1
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent sensors for the detection of hydrazine in environmental and biological systems: Recent advances and future prospects. https://app.cochat.ai/papers/10.1016/j.ccr.2020.213367
- The paper
- Zhang, X.-Y., Yang, Y.-S., Wang, W., Jiao, Q.-C., & Zhu, H.-L. (2020). Fluorescent sensors for the detection of hydrazine in environmental and biological systems: Recent advances and future prospects. Coordination Chemistry Reviews. https://doi.org/10.1016/j.ccr.2020.213367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.