The DOI matches its Crossref record; 263 of the 263 references it cites were found in a registry or an index.
AIE-based luminescence probes for metal ion detection
Abstract
Abstract The past two decades have witnessed significant advances in the field of aggregation-induced emission (AIE). Luminescent materials with AIE characteristics (AIEgens) are of great importance because they can show enhanced and improved properties for different high-tech applications. Metal ions are vital for all living species. In the recent years, the AIE platform has been widely adopted in the design and synthesis of metal ion-responsive luminescent probes because of its excellent photophysical properties such as microenvironment sensitivity, high signal-to-noise ratio, high photostability, high emission efficiency in the aggregated state, and large Stokes’ shift. In this review, we present an overview of the design principles of metal ion responsive AIEgens that can be generated using a modular approach. We have summarized the typical examples of metal ion responsive AIEgens, and their sensing mechanisms developed from 2005 to 2020.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Han, C., Huang, T., Liu, Q., Xu, H., Zhuang, Y., Li, J., Hu, J., Wang, A., & Xu, K. (2014) · Journal of Materials Chemistry C · doi:10.1039/c4tc01759e · Cited by 21
RetractedPrinciples of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationAggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationAggregation-induced emission: phenomenon, mechanism and applications
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Communications · doi:10.1039/b904665h · Cited by 4,115
Self-citationAggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Self-citationMarambio-Jones, C., & Hoek, E. M. V. (2010) · Journal of Nanoparticle Research · doi:10.1007/s11051-010-9900-y · Cited by 2,914
Prabhu, S., & Poulose, E. K. (2012) · International Nano Letters · doi:10.1186/2228-5326-2-32 · Cited by 2,278
Silver as Antibacterial Agent: Ion, Nanoparticle, and Metal
Chernousova, S., & Epple, M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205923 · Cited by 2,264
Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions
Kim, H. N., Ren, W. X., Kim, J. S., & Yoon, J. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15245a · Cited by 2,253
Cited by
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Metadata
- Authors
- Alam, P., Leung, N. L. C., Zhang, J., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z.
- Venue
- Coordination Chemistry Reviews
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 429
- Pages
- 213693
- ISSN
- 0010-8545 (ISSN-L)
- OpenAlex
- W3110822948
- Cited by
- 275
- References
- 263
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AIE-based luminescence probes for metal ion detection. https://app.cochat.ai/papers/10.1016/j.ccr.2020.213693
- The paper
- Alam, P., Leung, N. L. C., Zhang, J., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2021). AIE-based luminescence probes for metal ion detection. Coordination Chemistry Reviews. https://doi.org/10.1016/j.ccr.2020.213693
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.