Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Efficient removal of bisphenol A by superoxide radical and singlet oxygen generated from peroxymonosulfate activated with Fe0-montmorillonite

Yang, Shanshan, Wu, Pingxiao, Liu, Junqin, Chen, Meiqing, Ahmed, Zubair, Zhu, Nengwu·2018·Chemical Engineering Journal

Abstract

Abstract For eliminating organic pollutants from wastewater, Fe0 or Fe0-composites as catalyst for peroxymonosulfate (PMS) activation have attracted increasing attention in advanced oxidation processes. In this work, a novel Fe0-montmorillonite composites (Fe-Mt-C-H2) have been prepared by thermal reduction and used as an activator for PMS to remove bisphenol A (BPA). The removal efficiency of BPA (25 mg·L−1) and total organic carbon (TOC) were 99.3% and 70.6%, respectively, in the presence of Fe-Mt-C-H2 (0.4 g·L−1) and PMS (1 mM) at pH of 3. Electron paramagnetic resonance (EPR) spectroscopy and radical scavenger studies demonstrated that superoxide radical (O2 −) and singlet oxygen (1O2) were the crucial reactive oxygen species (ROS) in the Fe-Mt-C-H2/PMS system rather than sulfate (SO4 −) and hydroxyl radical (·OH). Besides, it was found that pH had a great influence on the catalytic oxidation rate of BPA and the Fe-Mt-C-H2 exhibited best catalytic performance and reusability at initial pH of 3. Furthermore, the constituents of the iron surface oxidation layer at different initial pH were investigated with X-ray photoelectron spectroscopy studies, which indicated that the major constituents were Fe3O4 in acidic solution and contained α-Fe2O3, FeO and FeSO4(s) in alkaline or neutral solution. The findings of this study provide new insights into the activation mechanism of PMS by Fe0-composites and exhibit a promising application of Fe-Mt-C-H2 in wastewater treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2018.04.175

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 360

Metadata

Authors
Yang, S., Wu, P., Liu, J., Chen, M., Ahmed, Z., & Zhu, N.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2018-10
Volume
350
Pages
484-495
ISSN
1385-8947 (ISSN-L)
OpenAlex
W2801376058
Cited by
360
References
54
FWCI
16.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficient removal of bisphenol A by superoxide radical and singlet oxygen generated from peroxymonosulfate activated with Fe0-montmorillonite. https://app.cochat.ai/papers/10.1016/j.cej.2018.04.175
The paper
Yang, S., Wu, P., Liu, J., Chen, M., Ahmed, Z., & Zhu, N. (2018). Efficient removal of bisphenol A by superoxide radical and singlet oxygen generated from peroxymonosulfate activated with Fe0-montmorillonite. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2018.04.175

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.