The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Degradation of atrazine by persulfate activation with copper sulfide (CuS): Kinetics study, degradation pathways and mechanism
Abstract
In this study, copper sulfide (CuS) was used as a catalyst to activate persulfate (PS) for atrazine (ATZ) degradation. A new method called one-eight-lives was proposed to investigate the kinetic parameters (i.e., atrazine concentration, CuS dosage, PS dosage). The t1/8 was calculated to analyze ATZ decay and degradation rate of ATZ, which could be expressed by the kinetic rate equation: −d[ATZ]/dt = (2.985 × 10−4 mmol L−1 min−1) [ATZ]0.023[PS]0.76318[CuS]0.80801. Besides, effects of the initial solution pH and the coexisting inorganic anions (i.e., nitrate ions (NO32−), chloride ions (Cl−), bicarbonate (HCO3−) and phosphate (HPO42−)) on ATZ degradation were also evaluated during the experiments. Also, the intermediate products were identified by ultrahigh performance liquid chromatograph-mass spectrometry (UPLC-MS). Based on the detected intermediates, possible reaction pathways were proposed. The stability and reusability of the CuS was investigated after three consecutive experiments. Characteristics of the fresh and used CuS were analyzed via SEM, EDS, XRD and XPS techniques. Furthermore, the different systems were set up to investigate the performance of CuS under the same experimental conditions. In addition, the radical scavengers (e.g., methanol, tert-butyl alcohol and phenol) experiences and PS decomposition study revealed that PS activation process occurred on the surface of CuS, and sulfate and hydroxyl radicals were the dominant active species for the ATZ degradation. The generation of sulfate and hydroxyl radicals was further confirmed by electron spin resonance (ESR). Besides, the generation of HO during the reaction process in CuS/PS system was quantified indirectly by HPLC. Finally, the possible reaction mechanism of CuS/PS system was proposed according to the comprehensive analysis. The findings of this study provided useful information for the application of CuS in recalcitrant organic contaminants degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, T., Chen, Y., Wang, Y., Le Roux, J., Yang, Y., & Croué, J.-P. (2014) · Environmental Science & Technology · doi:10.1021/es501218f · Cited by 798
Cited by
Li, N., Wang, Y., Cheng, X., Dai, H., Yan, B., Chen, G., Hou, L., & Wang, S. (2022) · Water Research · doi:10.1016/j.watres.2022.118896 · Cited by 360
Li, J., Wan, Y., Li, Y., Yao, G., & Lai, B. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2019.117782 · Cited by 355
Self-citationLi, Y., Dong, H., Li, L., Tang, L., Tian, R., Li, R., Chen, J., Xie, Q., Jin, Z., Xiao, J., et al. (2021) · Water Research · doi:10.1016/j.watres.2021.116850 · Cited by 351
Zhou, H., Zhang, H., He, Y., Huang, B., Zhou, C., Yao, G., & Lai, B. (2021) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2021.119900 · Cited by 338
Self-citationWei, K., Faraj, Y., Yao, G., Xie, R., & Lai, B. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.128783 · Cited by 274
Self-citation
Metadata
- Authors
- Peng, J., Lu, X., Jiang, X., Zhang, Y., Chen, Q., Lai, B., & Yao, G.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 354
- Pages
- 740-752
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2887249180
- Cited by
- 212
- References
- 1
- FWCI
- 9.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Degradation of atrazine by persulfate activation with copper sulfide (CuS): Kinetics study, degradation pathways and mechanism. https://app.cochat.ai/papers/10.1016/j.cej.2018.08.038
- The paper
- Peng, J., Lu, X., Jiang, X., Zhang, Y., Chen, Q., Lai, B., & Yao, G. (2018). Degradation of atrazine by persulfate activation with copper sulfide (CuS): Kinetics study, degradation pathways and mechanism. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2018.08.038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.