The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bio-electro-Fenton processes for wastewater treatment: Advances and prospects
Open accessAbstract
Abstract Water quality deterioration caused by a wide variety of persistent organic pollutants (POPs) has become a serious concern worldwide. Traditional advanced oxidation process (e.g., Fenton reaction) is often inadequate, unsafe, and require post-treatment to remove residual H2O2. In this context, the bioelectrochemical technology assisted advanced oxidation reactions (namely bio-electro-Fenton system) have found a niche where they can become dominant in the near future, especially for POPs removal. Compared to traditional Electro-Fenton technologies, the bio-electro-Fenton system greatly reduced the expenses on wastewater treatment in terms of electric energy consumption and operation costs. The bio-electro-Fenton system is becoming a versatile platform technology and offers a new solution for emerging environmental issues related to wastewater treatment. This paper critically reviews the existing literature about the degradation of POPs in bio-electro-Fenton system, especially with respect to the treatment performance associated with reactor design and main operating parameters. The review aims to assist researchers and engineers to gain fundamental understandings and critical view of bio-electro-Fenton system, and hopefully with the knowledge it could bring new opportunities for the future development of this promising wastewater treatment technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electro-Fenton Process and Related Electrochemical Technologies Based on Fenton’s Reaction Chemistry
Brillas, E., Sirés, I., & Oturan, M. A. (2009) · Chemical Reviews · doi:10.1021/cr900136g · Cited by 3,437
Cited by
Heterogeneous Fenton catalysts: A review of recent advances
Thomas, N., Dionysiou, D. D., & Pillai, S. C. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.124082 · Cited by 889
Bello, M. M., Abdul Raman, A. A., & Asghar, A. (2019) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2019.03.028 · Cited by 435
Deng, F., Olvera-Vargas, H., Zhou, M., Qiu, S., Sirés, I., & Brillas, E. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00684 · Cited by 409
Brillas, E., & Garcia-Segura, S. (2020) · Separation and Purification Technology · doi:10.1016/j.seppur.2019.116337 · Cited by 394
Ganiyu, S. O., Martínez-Huitle, C. A., & Rodrigo, M. A. (2020) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2020.118857 · Cited by 334
Metadata
- Authors
- Li, X., Chen, S., Angelidaki, I., & Zhang, Y.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 354
- Pages
- 492-506
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2886276839
- Cited by
- 216
- References
- 1
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bio-electro-Fenton processes for wastewater treatment: Advances and prospects. https://app.cochat.ai/papers/10.1016/j.cej.2018.08.052
- The paper
- Li, X., Chen, S., Angelidaki, I., & Zhang, Y. (2018). Bio-electro-Fenton processes for wastewater treatment: Advances and prospects. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2018.08.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.