The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A ratiometric optical thermometer with high sensitivity and superior signal discriminability based on Na3Sc2P3O12: Eu2+, Mn2+ thermochromic phosphor
Abstract
Abstract Dual-emitting and thermochromic Eu2+, Mn2+ co-doped Na3Sc2P3O12 (NSPO) phosphor was synthesized by a modified solid-state method. Its crystal structure and luminescent properties, especially temperature-dependent fluorescence properties are discussed in detail. Na3Sc2P3O12: Eu2+, Mn2+ simultaneously exhibits two broad bands under single UV excitation, i.e. Eu2+ blue emission band centered at 460 nm and Mn2+ red emission band centered at 600 nm with quantum efficiency of >90%. The dual emissions in Na3Sc2P3O12: Eu2+, Mn2+ have different thermal responses due to the competition between trap-to-activator energy transfer and thermal quenching, by which a novel self-referencing non-invasion optical thermometer with high sensitivity and superior signal discriminability was designed. The temperature sensing properties of Na3Sc2P3O12: Eu2+, Mn2+ in a wide range of 293–473 K were analyzed, which shows good linear relationship between ratiometric intensity and temperature (R2 > 0.999) as well as high sensitivity (1.556% K−1). Besides, the emitting color is highly sensitive to the temperature variation. The results suggest that Na3Sc2P3O12: Eu2+, Mn2+ could be a good candidate high-sensitive for optical thermometry and safety sign in high temperature environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shannon, R. D. (1976) · Acta Crystallographica Section A · doi:10.1107/s0567739476001551 · Cited by 66,145
A zero-thermal-quenching phosphor
Kim, Y. H., Arunkumar, P., Kim, B. Y., Unithrattil, S., Kim, E., Moon, S.-H., Hyun, J. Y., Kim, K. H., Lee, D., Lee, J.-S., et al. (2017) · Nature Materials · doi:10.1038/nmat4843 · Cited by 1,065
Song, E., Zhou, Y., Yang, X., Liao, Z., Zhao, W., Deng, T., Wang, L., Ma, Y., Ye, S., & Zhang, Q. (2017) · ACS Photonics · doi:10.1021/acsphotonics.7b00852 · Cited by 215
Wang, C., Lin, H., Xu, Z., Huang, Y., Humphrey, M. G., & Zhang, C. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11317 · Cited by 201
Achieving long-term zero-thermal-quenching with the assistance of carriers from deep traps
Fan, X., Chen, W., Xin, S., Liu, Z., Zhou, M., Yu, X., Zhou, D., Xu, X., & Qiu, J. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc00511g · Cited by 112
El‐Shinawi, H., Regoutz, A., Payne, D. J., Cussen, E. J., & Cussen, S. A. (2018) · Journal of Materials Chemistry A · doi:10.1039/c7ta08715b · Cited by 85
C-QDs@UiO-66-(COOH)2 Composite Film via Electrophoretic Deposition for Temperature Sensing
Feng, J., Gao, S., Shi, J., Liu, T., & Cao, R. (2018) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.7b02595 · Cited by 85
A zero-thermal-quenching and color-tunable phosphor LuVO4: Bi3+, Eu3+ for NUV LEDs
Zhang, X., Zhu, Z., Guo, Z., Mo, F., & Wu, Z. (2018) · Dyes and Pigments · doi:10.1016/j.dyepig.2018.03.071 · Cited by 78
Self-citationWu, L., Wang, B., Zhang, Y., Li, L., Wang, H. R., Yi, H., Kong, Y. F., & Xu, J. (2014) · Dalton Transactions · doi:10.1039/c4dt01524j · Cited by 74
Zhang, J., Zhang, X., Zhang, J., Ma, W., Ji, X., Liao, S., Qiu, Z., Zhou, W., Yu, L., & Lian, S. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc04262k · Cited by 68
Self-citation
Metadata
- Authors
- Zhang, X., Zhu, Z., Guo, Z., Sun, Z., & Chen, Y.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 356
- Pages
- 413-422
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2890954935
- Cited by
- 330
- References
- 10
- FWCI
- 11.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.